Product Details
DEYE Hybrid Inverter 8KW Battery Voltage :40~60V, Max Charge/discharge Current 190A,PV Input Voltage:500V, Self-Adapton to BMS, Max DC I/P PWR:10400W, MPPT Trackers 2, MAX DC I/P PWR:10400W, 50Hz 230VAC (Single Phase), RS485, CAN, 670x420x233mm, 32kg, IP6
Hybrid Inverter 8KW Battery
Feature
Higher Yields
- Improve self-consumption ratio up to 80%, reducing your electricity bill
- DC/AC ra ratio up to 1.3, completely suitable for double-side PV modular
- Two MPPT design, Max. efficiency of 97.6%
- LCD Touch screen and buttons, easy operation
- Compable with lithium-ion battery and lead acid battery
- Web browser and mobile App monitoring supported
- PV lighting protection, Anti-islanding protection, Leakage current protection etc
- Support store energy from DG when needed, ensure the system working within 7*24H
- IP65 protection degree, adapt to indoor and outdoor
- Automatically switch from on-grid to off-grid mode within 5ms
- Zero exporting function, fast reaction within 200ms in zero export mode
- Programmable charging and discharging schedule
- Both wind turbines and solar panels can be connected as DC input power
- Max. 16 units can be paralleled for higher system power
- Retrofitting of existing solar system to energy storage system
User-friendly
Reliable
Smart
Specifications
Battery Input Data
r Li- lean - Battery Voltage Range (V) 40~60V
- Max Charging Current (A) 190A
- Max Discharging Current (A) 190A
- Charging Curve 3 Stages/Equalization
- Extreme Temperature Sensor Included
- Charging Strategy for Li- Ion Battery Self- adaption to BMS
- Max DC Input Power (W) 10400W
- PV Input Voltage (V) 370V(lO0V~500V)
- MPPT Range (V) 125V-425V
- Start - up Voltage (V) 125V
- PV Input Current (A) 1SA+18A
- Nc1.ofMPPT Trackers 2
- No of Strings Per MPPT Tracker 2+2
- Rated AC Output and UPS Power (W) 8000W
- Max AC Output Power (W) 8800W
- Peak Power (off grid) 2 times of rated power, 10 S
- AC Output Rated Current(A) 33.4A/35A
- Max.AC Current(A) 38.3A/40A
- Max Continuous AC Passthrough(A) 50A
- Output Frequency and Voltage 50Hz- 230Vac (single phase)
- Grid Type Single Phase
- Current Harmonic Distortion THD<3% (Linear load<1.5%)
- Max Efficiency 97.60%
- Euro Efficiency 97.00%
- MPPT Efficiency 99.90%
- PV Arc Fault Detection integrated (Except European Type)
- PV input Lightning Protection Integrated
- Anti - islanding Protection Integrated
- PV String Input Reverse Polarity Protection Integrated
- Insulation Resistor Detect ion Integrated
- Residual Current Monitoring Unit Integrated
- Output Over Current Protection Integrated
- Output Shorted Protection Integrated
- Output Over Voltage Protection Integrated
- Grid Regulation AS4777, N RS2017, G98, G99, IEC61683, IEC62 116, IEC6 1727
- Safety Regulation IEC62109 - l, IEC6210 9-2
- EMC EN61000 -6- l, EN61000 -6-3
- Operating Temperature Range (c) -25- 60 t, >45 °C. Derating
- Cc>c>ling Fan
- Noise (dB) <30
- Communication with BMS RS485; CAN
- Weight (kg) 32
- Size (Length x Width x Height mm) 670 X 420 X 233mm
- Protection Degree IP65
- Installation Style Wall-mounted
- Warranty 5 years
PV String Input Data
AC Output Data
Efficiency
Protection
Certifications and Standards
General Data
Downloads
Additional Information
| Device | Inverter |