Product Details
Current Loop Calibrator 24MA
Overview
Features
Specification
Current Measurement:
Current Sourcing:
Current Simulation:
Loop Power:
Voltage measurement:
Environmental Specifications
Safety Specifications
Mechanical & General Specifications
- Range: 0 to 24 mA
- Resolution: 0.001 mA
- Accuracy: 0.015% Rdg + 2 LSD
Current Sourcing:
- Range: 0 to 20 mA or 4 to 20 mA
- Accuracy: 0.015% Rdg + 2 LSD
- Drive Capability: 1200 O; 950 O at 20 mA in HART mode
Current Simulation:
- Range: 0 to 20 mA or 4 to 20 mA
- Accuracy: 0.015% Rdg + 2 LSD
- Ext. loop voltage requirement: 12-30 V
Loop Power:
- While measuring mA, 24 V
Voltage measurement:
- Range: 0 to 28 V DC
- Resolution: 1 mV
- Accuracy: 0.015% Rdg + 2 LSD
Environmental Specifications
- Operating Temperature: -10ºC to 55ºC
- Storage Temperature: -30ºC to 60ºC
- Humidity (Without Condensation): 0 to 90% (0ºC to 35ºC); 0 to 70% (35ºC to 55ºC)
- Temperature Coefficient: -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC
Safety Specifications
- Safety: CSA C22.2 No. 1010.1:1992
- EMC: EN50082-1:1992 and EN55022:1994 Class B
- Maximum voltage: 30V
Mechanical & General Specifications
- Size: 152 x 70 x 41 mm
- Weight: 224 g (340 g including holster)
- Batteries: One 9V battery Alkaline
- Warranty: Three years
- Shock & Vibration: per MIL-T-28800 for a Class 2 Instrument
- Display current and % of span: Yes
- Auto step, auto ramp: Yes
- Span Check: Yes