{"product_id":"usr-can315-canfd-to-ethernet-con","title":"USR CAN315 CANFD TO ETHERNET CON","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eAn Industrial CANFD to Ethernet Converter Gateway. It Supports Canopen and Modbus Protocols for Efficient Communication between CAN FD Networks and Ethernet Devices in Industrial Automation.\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eCANFD to Ethernet Converter Gateway\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003eThe USR-CAN315\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e is an industrial protocol converter that allows you to connect a \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003eCAN FD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e bus to an \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003eEthernet network (10\/100 Mbps)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e or other network devices. The device supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003eCAN 2.0A\/2.0B\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003eCAN FD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e standards , enabling the integration of both traditional and modern CAN devices in a single environment.\u003c\/span\u003e\u003c\/p\u003e\r\n\u003ch4\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eOperating modes\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\r\n\u003cp\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eThe USR-CAN315 offers \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003efive operating modes\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e that provide maximum flexibility in transmitting and processing data between the CAN FD bus and Ethernet or Modbus systems:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003etransparent conversion\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003etransparent conversion with \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eID\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003estandard mode\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan dir=\"auto\"\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003eModbus\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e protocol conversion\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003ecustom conversion\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eThe device is compact and easy to mount on a DIN rail, measuring \u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e110 x 27 x 76.1 mm\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e . Powered by a \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e9–36 V DC\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e supply (12 V 1 A recommended), it features one \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eCAN FD\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e port compliant with CAN 2.0A\/2.0B and a \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e10\/100 Mbps RJ45\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e network port with auto-adaptive connectivity. The USR-CAN315 operates in a wide temperature range \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eof -40–85 °C\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e and humidity up to 95% RH. Built-in filtering, frame packetization, and Modbus TCP support ensure flexible and secure data transmission in demanding industrial environments. Additionally, the device is resistant to \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eESD, surges, and EFT interference\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e , ensuring reliable operation in harsh environments.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cul\u003e\r\n\u003cli\u003eOperating Temperature range: -40 °C ~ +85 °C\u003c\/li\u003e\r\n\u003cli\u003eEMC Immunity: level 3\u003c\/li\u003e\r\n\u003cli\u003eCAN Filters: up to 32 sets of configurable filters\u003c\/li\u003e\r\n\u003cli\u003eCAN FD Transmission Speed: up to 5 Mb\/s in the data field\u003c\/li\u003e\r\n\u003cli\u003ePower Supply: DC 9–36 V\u003c\/li\u003e\r\n\u003cli\u003eMounting: on a DIN rail\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ctable border=\"1\"\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003cth colspan=\"2\"\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eUSR-CAN315 Specifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eBasic parameters\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eOperating voltage\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eDC 9～36V (12V 1A recommended)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eDimensions\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e110 × 27 × 76.1 mm\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eInstallation method\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eDIN rail mounting\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eFactory reset\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eLong press the RESET button\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eSignal diodes\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003ePOWER, WORK, NET, CAN\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eInterface parameters\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eCAN port\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e1 × CAN, support CAN FD, compatible with CAN 2.0A\/2.0B\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eCAN transmission speed\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eArbitration: 5K~1Mbps; Data: 100K~5Mbps\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eTerminal resistor\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eBuilt-in 2 × 120 Ω CAN bus resistor\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eNetwork port\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eRJ45 10\/100 Mbps, automatic cross-connect adaptation\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eWork environment\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eOperating temperature\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e-40 ~ 85 ℃\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eStorage temperature\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e-40 ~ 105 ℃\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eWorking humidity\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e5% ~ 95% RH (non-condensing)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eStorage humidity\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e5% ~ 95% RH (non-condensing)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eSoftware Features\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eNetwork protocols\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eTCP Server, TCP Client, UDP Server, UDP Client \u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eModbus gateway\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eCAN(FD) ↔ Modbus TCP (Master\/Slave)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eBroadcast News\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eUp to 64 broadcast messages\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eReceiving messages\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eSupports 64 incoming messages\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eProtocol conversion modes\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e5 protocol conversion modes\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eCAN ID support\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eSupport for standard and extended frames\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eFrame ID Filtering\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eSupports only standard frames, only remote frames and own frames (≤ 32 groups)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eFrame Packing\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eDetermining the number and timing of frame packets\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eTransmission direction\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eBidirectional; Network only → CAN; CAN only → Network\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eFirmware update\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eSupport for updates via PC software\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eParameter configuration\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eAT Commands and Computer Software\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eOther functions\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eSupport for heartbeat and registration packets; normal, loopback, and listening modes \u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eProtection parameters\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eESD protection\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eAir discharge: 8 kV; contact: 6 kV\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eEFT\/Burst Protection\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003ePower supply circuit: 2 kV; network port and CAN port: 1 kV\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eSurge resistance\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003ePower supply circuit: 1 kV (differential), 2 kV (common); CAN port: 2 kV (common); network port: 1 kV\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003eThe set includes:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e1 x USR-CAN315\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e1 x Network cable\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e1 x Certificate of Conformity \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e1 x original packaging\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eEthernet Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eEthernet | Converter | Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"UsrIoT","offers":[{"title":"Default Title","offer_id":45624710725676,"sku":"USR CAN315 CANFD TO ETHERNET CON","price":800.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/usr-can315-canfd-to-ethernet-con-7158454.jpg?v=1781108861","url":"https:\/\/xytron.ae\/products\/usr-can315-canfd-to-ethernet-con","provider":"Xytron","version":"1.0","type":"link"}