{"product_id":"maj-mtd8","title":"MAJ MTD8","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eTimer 24Hour 7Day ON\/OFF Programmer\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003e24Hour 7Day ON\/OFF  Timer Programmer\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe MTD8 is a 30A 16 On\/Off Digital Programmable Timer that is easy-to-use, quick to set and will maximize your savings. When installing the MTD8 for the first time, press the reset button to activate the timer.\u003c\/p\u003e\r\n\u003cp\u003eThe introduction of a timer will improve your energy savings up to 66%. Switching the geyser off\/on manually is not good practice as circuit breakers are not designed to be switched often and will eventually damage which can be costly to replace.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cul\u003e\r\n\u003cli\u003eDin Rail and Samite Rail Mounted\u003c\/li\u003e\r\n\u003cli\u003eAdvanced weekly settings\u003c\/li\u003e\r\n\u003cli\u003eRepeat programs with 16 ON\/OFF settings, 18 pulse settings, and a manual ON\/OFF switch\u003c\/li\u003e\r\n\u003cli\u003eLithium battery back up in the event of a power failure\u003c\/li\u003e\r\n\u003cli\u003eMANUAL button changes between Manual ON\/OFF, ON AUTO and AUTO OFF\u003c\/li\u003e\r\n\u003cli\u003eTerminology: ON (Always ON), OFF (Always OFF), AUTO ON (Timer remains ON until the next OFF programmed setting) \/ AUTO OFF (Timer remains OFF until next programmed ON setting and turns OFF as per programmed OFF settings)\u003c\/li\u003e\r\n\u003cli\u003eAUTO OFF – Automatically turns the timer ON and OFF as per the programmed settings\u003c\/li\u003e\r\n\u003cli\u003eWhile programming any function, 30 seconds of inactivity will exit all setting menu\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e*\u003cstrong\u003eNOTE: \u003c\/strong\u003ePress Reset Button to activate timer (only required when first installed).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\r\n\u003ctd\u003e220V – 240V AC 50\/60Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVoltage Limit\u003c\/td\u003e\r\n\u003ctd\u003e±10%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResistive Loads (Max)\u003c\/td\u003e\r\n\u003ctd\u003e30A (4400W)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMinimum Interval\u003c\/td\u003e\r\n\u003ctd\u003e1 minute\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCountdown Interval\u003c\/td\u003e\r\n\u003ctd\u003e1 second – 99 minutes \u0026amp; 59 seconds\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e18 Pulse Intervals\u003c\/td\u003e\r\n\u003ctd\u003e1 second – 59 minutes \u0026amp; 59 seconds\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\r\n\u003ctd\u003e-10°C ~ 40°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAmbient Humidity\u003c\/td\u003e\r\n\u003ctd\u003e35%RH ~ 85%RH\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd\u003e150g\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCertification\u003c\/td\u003e\r\n\u003ctd\u003eIEC60730-1, IEC60730-2-7\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D4223052203.pdf\"\u003eDatasheet - MAJ MTD8\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D0936849033.pdf\"\u003eUser Manual - MAJ MTD8\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eTimer Programmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e24Hour | 7Day | ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Major Tech","offers":[{"title":"Default Title","offer_id":44755506987052,"sku":"MAJ MTD8","price":310.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/maj-mtd8-559878.jpg?v=1757327095","url":"https:\/\/xytron.ae\/products\/maj-mtd8","provider":"Xytron","version":"1.0","type":"link"}