{"product_id":"lrs-350-5","title":"LRS-350-5","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eMeanwell Metal Case Switch Mode Power Supply Input: 180~264Vac\/240-340Vdc , Output 5Vdc @ 60A 300W , Voltage Adjustable Range:4.5~5.5Vdc , Ripple \u0026amp; Noise:150mVp-p , 215x115x30mm , 0,76kg\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eMetal Case Switch Mode Power Supply Input\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003e\u003cp\u003eLRS-350 series is a 350W single-output enclosed type power supply with 30mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 3.3V, 4.2V, 5V, 12V, 15V, 24V, 36V and 48V. In addition to the high efficiency up to 89%, with the built-in long life fan LRS-350 can work under -25~\u003cbr\u003e+70℃ with full load. Delivering an extremely low no load power consumption (less than 0.75W), it allows the end system to easily meet the worldwide energy requirement. LRS-350 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as UL60950-1. LRS-350 series serves as a high price-to-performance power supply solution for various industrial applications.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch2\u003eFeature\u003c\/h2\u003e\n\u003cdiv\u003e\u003cul style=\"list-style-type: circle;\"\u003e\r\n\u003cli\u003eAC input range selectable by switch\u003c\/li\u003e\r\n\u003cli\u003eWithstand 300VAC surge input for 5 second\u003c\/li\u003e\r\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/\u003cbr\u003eOver temperature\u003c\/li\u003e\r\n\u003cli\u003eForced air cooling by built-in DC fan\u003c\/li\u003e\r\n\u003cli\u003eBuilt-in cooling Fan ON-OFF control\u003c\/li\u003e\r\n\u003cli\u003e1U low profile\u003c\/li\u003e\r\n\u003cli\u003eWithstand 5G vibration test\u003c\/li\u003e\r\n\u003cli\u003eLED indicator for power on\u003c\/li\u003e\r\n\u003cli\u003eNo load power consumption\u0026lt;0.75W\u003c\/li\u003e\r\n\u003cli\u003e100% full load burn-in test\u003c\/li\u003e\r\n\u003cli\u003eHigh operating temperature up to 70℃\u003c\/li\u003e\r\n\u003cli\u003eHigh efficiency, long life and high reliability\u003c\/li\u003e\r\n\u003cli\u003e3 years warranty\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003eOUTPUT\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDC VOLTAGE: 5V\u003c\/li\u003e\r\n\u003cli\u003eRATED CURRENT: 60A\u003c\/li\u003e\r\n\u003cli\u003eCURRENT RANGE: 0 ~ 60A\u003c\/li\u003e\r\n\u003cli\u003eRATED POWER: 300W\u003c\/li\u003e\r\n\u003cli\u003eRIPPLE \u0026amp; NOISE (max.) Note.2: 150mVp-p\u003c\/li\u003e\r\n\u003cli\u003eVOLTAGE ADJ. RANGE: 4.5 ~ 5.5V\u003c\/li\u003e\r\n\u003cli\u003eVOLTAGE TOLERANCE Note.3: ±3.0%\u003c\/li\u003e\r\n\u003cli\u003eLINE REGULATION Note.4 : ±0.5%\u003c\/li\u003e\r\n\u003cli\u003eLOAD REGULATION Note.5: ±2.0%\u003c\/li\u003e\r\n\u003cli\u003eSETUP, RISE TIME:1300ms, 50ms\/115VAC at full load \u003c\/li\u003e\r\n\u003cli\u003eHOLD UP TIME (Typ.):12ms\/115VAC at full load\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eINPUT\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eVOLTAGE RANGE:90 ~ 132VAC \/ 180 ~ 264VAC by switch\u003c\/li\u003e\r\n\u003cli\u003eFREQUENCY RANGE: 47 ~ 63Hz\u003c\/li\u003e\r\n\u003cli\u003eEFFICIENCY (Typ.):83.5%\u003c\/li\u003e\r\n\u003cli\u003eAC CURRENT (Typ.): 6.8A\/115VAC 3.4A\/230VAC\u003c\/li\u003e\r\n\u003cli\u003eINRUSH CURRENT (Typ.): 60A\/115VAC 60A\/230VAC\u003c\/li\u003e\r\n\u003cli\u003eLEAKAGE CURRENT: \u0026lt;2mA \/ 240VAC\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003ePROTECTION\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eOVER LOAD: 110 ~ 140% rated output power\u003cbr\u003e                    Protection type : Hiccup mode, recovers automatically after fault condition is removed\u003c\/li\u003e\r\n\u003cli\u003eOVER VOLTAGE: 5.75 ~ 6.75V \u003cbr\u003e                    Protection type : Hiccup mode, recovers automatically after fault condition is removed\u003c\/li\u003e\r\n\u003cli\u003eOVER TEMPERATURE: Hiccup mode, recovers automatically after fault condition is removed\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eFUNCTION\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eFAN ON\/OFF CONTROL (Typ.): RTH3≧50℃ FAN ON, ≦40℃ FAN OFF\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eENVIRONMENT\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eWORKING TEMP: -25 ~ +70℃ (Refer to \"Derating Curve\")\u003c\/li\u003e\r\n\u003cli\u003eWORKING HUMIDITY: 20 ~ 90% RH non-condensing\u003c\/li\u003e\r\n\u003cli\u003eSTORAGE TEMP., HUMIDITY:-40 ~ +85℃, 10 ~ 95% RH\u003c\/li\u003e\r\n\u003cli\u003eTEMP. COEFFICIENT: ±0.03%\/℃ (0 ~ 50℃)\u003c\/li\u003e\r\n\u003cli\u003eVIBRATION:10 ~ 500Hz, 5G 10min.\/1cycle, 60min. each along X, Y, Z axes\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eSAFETY\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSAFETY STANDARDS: UL60950-1 approved\u003c\/li\u003e\r\n\u003cli\u003eWITHSTAND VOLTAGE: I\/P-O\/P:3KVAC I\/P-FG:2KVAC O\/P-FG:0.5KVAC\u003c\/li\u003e\r\n\u003cli\u003eISOLATION RESISTANCE: I\/P-O\/P, I\/P-FG, O\/P-FG:100M Ohms\/500VDC\/ 25℃\/ 70% RH\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eOTHERS\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMTBF:327.9K hrs min. MIL-HDBK-217F (25℃)\u003c\/li\u003e\r\n\u003cli\u003eDIMENSION: 215*115*30mm (L*W*H)\u003c\/li\u003e\r\n\u003cli\u003ePACKING: 0.76Kg; 15pcs\/12.4Kg\/0.78CUFT\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eNOTE:\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eAll parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.\u003c\/li\u003e\r\n\u003cli\u003eRipple \u0026amp; noise are measured at 20MHz of bandwidth by using a 12\" twisted pair-wire terminated with a 0.1uf \u0026amp; 47uf parallel capacitor.\u003c\/li\u003e\r\n\u003cli\u003eTolerance : includes set up tolerance, line regulation and load regulation.\u003c\/li\u003e\r\n\u003cli\u003eLine regulation is measured from low line to high line at rated load.\u003c\/li\u003e\r\n\u003cli\u003eLoad regulation is measured from 0% to 100% rated load.\u003c\/li\u003e\r\n\u003cli\u003eLength of set up time is measured at cold first start. Turning ON\/OFF the power supply very quickly may lead to increase of the set up time.\u003c\/li\u003e\r\n\u003cli\u003eThe 150% peak load capability is built in for up to 1 second for 12~48V.LRS-350 will enter hiccup mode if the peak load is delivered\u003cbr\u003efor over 1 second and will recover once it resumes to the rated current level(115VAC\/230VAC).\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D2549373796.pdf\"\u003eData Sheet - LRS-350-5\u003c\/a\u003e\u003c\/li\u003e\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSwitch Mode | Power Supply Input\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":45625462423596,"sku":"LRS-350-5","price":1250.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/lrs-350-5-814210.jpg?v=1781022429","url":"https:\/\/xytron.ae\/products\/lrs-350-5","provider":"Xytron","version":"1.0","type":"link"}