{"product_id":"fluke-375fc","title":"FLUKE 375FC","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eClamp Meter 999.9A AC\/DC 1000V True-RMS 6000kOhm Capacitance : 1uF~1,000uF Frequency 5-500.0Hz CATIII 1000V , CATIV600V\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eFC True-RMS AC\/DC Clamp Meter\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 375 FC True-RMS AC\/CD Clamp Meter measures very low voltage and very high resistance\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eThe Fluke 375 FC, part of the Fluke Connect family of wireless test tools, delivers high performance features and ease of use. It features a VFD low-pass filter for accurate motor drive measurements and wireless communications to transmit results to a smartphone via Fluke Connect\u003c\/p\u003e\r\n\u003cp\u003eThe 375 FC offers most of the features of the Fluke 376 FC including compatibility with the iFlex flexible current probe but, unlike the 376 FC, it does not include the iFlexÂ® probe in the package. You can measure AC and DC current to 600 A and voltage up to 1000 V with the fixed jaw clamp. Or connect an optional iFlexÂ® flexible current probe to expand your measurement range to 2500 A AC. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access individual wires.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWireless connectivity improves productivity\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eUsing its Bluetooth connectivity to Apple and Android devices, you can read the 375 FC results a safe distance away on your smartphone, wearing less PPE. You can create and send reports in email right from the field and save results to the cloud. You can also converse with colleagues in real-time with ShareLiveâ„¢ video calls.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eVersatile performance\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eWith True-RMS AC voltage and current measurements, the 375 enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 375 FC Clamp Meter is the direct replacement for the Fluke 375 Clamp Meter.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCompatible with optional TPAK magnetic hanging strap\u003c\/li\u003e\r\n\u003cli\u003eComes with batteries, soft carrying case, and three-year warranty\u003c\/li\u003e\r\n\u003cli\u003eFeatures CAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\r\n\u003cli\u003eMeasures capacitance to 1000 ÂµF\u003c\/li\u003e\r\n\u003cli\u003eIncludes True-RMS voltage and current measurements to accurately measure non-linear signals\u003c\/li\u003e\r\n\u003cli\u003eMeasures frequency to 500 Hz and resistance to 60 kâ„¦ with continuity detection\u003c\/li\u003e\r\n\u003cli\u003eIncludes Min\/Max\/Avg and inrush recording to capture variations automatically\u003c\/li\u003e\r\n\u003cli\u003eOffers 500 mV DC measurement range to interface with other accessories\u003c\/li\u003e\r\n\u003cli\u003eRuns on two AA alkaline batteries\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003eAC Current via Jaw\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e600.0 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolutionÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eAccuracyÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2% Â±5 digits (10 Hz to 100 Hz)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5% Â±5 digits (100-500 Hz)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eCrest Factor (50 Hz\/60 Hz)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e3 @ 500 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5 @ 600 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eAC Current via Flexible Current Probe\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2500 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 A (â‰¤ 600 A)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 A (â‰¤ 2500 A)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e3% Â±5 digits (5 â€“ 500 Hz)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"4\"\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e3.0 at 1100 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e2.5 at 1400 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1.42 at 2500 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003ePosition Sensitivity\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003e\u003cimg src=\"https:\/\/media.fluke.com\/f3cfc638-13b3-4358-9cd8-b108002b2e9f_original__size.jpg\" alt=\"Flexible current probe\" width=\"100\" height=\"181\"\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eÂ \u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003ei2500-10 Flex\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003ei2500-18 Flex\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eA\u003c\/td\u003e\r\n\u003ctd\u003eÂ \u003c\/td\u003e\r\n\u003ctd\u003eÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\r\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\r\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eError\u003c\/td\u003e\r\n\u003ctd\u003eÂ±0.5 %\u003c\/td\u003e\r\n\u003ctd\u003eÂ±0.5 %\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eB\u003c\/td\u003e\r\n\u003ctd\u003eÂ \u003c\/td\u003e\r\n\u003ctd\u003eÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\r\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\r\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eError\u003c\/td\u003e\r\n\u003ctd\u003eÂ±1.0 %\u003c\/td\u003e\r\n\u003ctd\u003eÂ±1.0 %\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eC\u003c\/td\u003e\r\n\u003ctd\u003eÂ \u003c\/td\u003e\r\n\u003ctd\u003eÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDistance from Optimum\u003c\/td\u003e\r\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\r\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eError\u003c\/td\u003e\r\n\u003ctd\u003eÂ±2.0 %\u003c\/td\u003e\r\n\u003ctd\u003eÂ±2.0 %\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eDC Current\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e600.0 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2% Â±5 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eAC Voltage\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 V (â‰¤600.0 V)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 V (â‰¤1000 V)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1.5% Â±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eDC Voltage\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 V (â‰¤600.0 V)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 V (â‰¤1000 V)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1% Â±5 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003emV dc\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e500.0 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1% Â±5 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eFrequency via Jaw\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolutionÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracyÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.5% Â±5 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eTrigger levelÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e5 Hz to 10 Hz, â‰¥10 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e10 Hz to 100 Hz, â‰¥5 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eFrequency via Flexible Current Probe\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolutionÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracyÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.5% Â±5 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eTrigger levelÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e5 Hz to 20 Hz, â‰¥25 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e20 Hz to 100 Hz, â‰¥20 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e100 Hz to 500 Hz, â‰¥25 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eResistance\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e60 kÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 Î© (â‰¤600 Î©)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 Î© (â‰¤6000 Î©)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e10 Î© (â‰¤60 kÎ©)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1% Â±5 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eCapacitance\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1000 Î¼F\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 Î¼F (â‰¤ 100 Î¼F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1 Î¼ F (â‰¤ 1000 Î¼F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1% Â±4 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eMechanical Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBatteries\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-10 Â°C to +50 Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-40 Â°C to +60 Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eOperating humidity -\u003cbr\u003enon-condensing (\u0026lt; 10Â°C)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eâ‰¤90% RH (at 10 Â°C to 30 Â°C)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eâ‰¤75% RH (at 30 Â°C to 40 Â°C)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e3000 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e12,000 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e249 x 85 x 45 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e395 g\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eJaw opening\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e34 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFlexible current probe diameter\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e7.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFlexible current probe cable length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1.8 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"4\"\u003eSafety\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eIEC 61010-1, Pollution Degree 2\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eIP rating\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRadio Frequency Certification FCC ID\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eT68-FBLE IC:6627A-FBLE\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"4\"\u003eInternational\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eCISPR 11: Group 1, Class A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eKorea (KCC)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTemperature coefficients\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eAdd 0.1 x specified accuracy for each degree C above 28 Â°C or below 18 Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D3812878315.pdf\"\u003eDatasheet - Fluke-370\u003c\/a\u003e\u003c\/li\u003e\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eClamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eFC | True-RMS | AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45627368898604,"sku":"FLUKE 375FC","price":16265.31,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/fluke-375fc-5567636.jpg?v=1781042116","url":"https:\/\/xytron.ae\/products\/fluke-375fc","provider":"Xytron","version":"1.0","type":"link"}