{"product_id":"fluke-374fc","title":"FLUKE 374FC","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eClamp Meter 600A AC\/DC 1000V True-RMS 6000Ohm Capacitance : 1uF~1,000uF CATIII 1000V, CATIV600V\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eTrue-RMS AC\/DC Clamp Meter\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 374 FC delivers advanced troubleshooting performance and wireless connectivity\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eThe Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting. Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlexÂ® flexible current probe to measure all the way to 2500 A. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Î©.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eUse wireless connectivity to keep a safe distance\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eThe 374 FC is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices. That means you can read the results out of the arc flash zone, wearing less PPE. You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLiveâ„¢ video calls.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eVersatile feature set\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eWith True-RMS AC voltage and current measurements, the 374 FC enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 374 FC Clamp Meter is the direct replacement for the Fluke 374 Clamp Meter.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCompatible with optional TPAK magnetic hanging strap\u003c\/li\u003e\r\n\u003cli\u003eComes with soft carrying case, batteries, and three-year warranty\u003c\/li\u003e\r\n\u003cli\u003eMeasures capacitance to 1000 ÂµF\u003c\/li\u003e\r\n\u003cli\u003eFeatures CAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\r\n\u003cli\u003eProvides True-RMS voltage and current measurements to accurately measure non-linear signals\u003c\/li\u003e\r\n\u003cli\u003eIncludes Min\/Max\/Avg and inrush recording to capture variations automatically\u003c\/li\u003e\r\n\u003cli\u003eRuns on two AA alkaline batteries\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"5\"\u003eAC Current via Jaw\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e600.0 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e2% Â±5 digits (10 Hz to 100 Hz)\u003cbr\u003e2.5% Â±5 digits (100-500 Hz)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCrest Factor (50 Hz\/60 Hz)\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e2.5 @ 600 A\u003cbr\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"5\"\u003eAC Current via Flexible Current Probe\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e2500 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e0.1 A (â‰¤ 600 A)\u003cbr\u003e1 A (â‰¤ 2500 A)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e3% Â±5 digits (5 â€“ 500 Hz)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e2.5 at 1400 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"5\"\u003ePosition Sensitivity\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"5\"\u003e\u003cimg src=\"https:\/\/media.fluke.com\/f3cfc638-13b3-4358-9cd8-b108002b2e9f_original%20file.png\" alt=\"Flexible current probe\" width=\"100\" height=\"181\"\u003e\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDistance from Optimum\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eÂ \u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003ei2500-10 Flex\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003ei2500-18 Flex\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eError\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\r\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±0.5 %\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\r\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±1.0 %\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\r\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±2.0 %\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"small-font nobold\" colspan=\"5\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"5\"\u003eDC Current\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e600.0 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e2% Â±5 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"5\"\u003eAC Voltage\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e0.1 V (â‰¤600.0 V)\u003cbr\u003e1 V (â‰¤1000 V)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e1.5% Â±5 digits (20 Hz to 500 Hz)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"5\"\u003eDC Voltage\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e0.1 V (â‰¤600.0 V)\u003cbr\u003e1 V (â‰¤1000 V)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e1% Â±5 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"5\"\u003emV dc\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e500.0 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e0.1 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e1% Â±5 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"5\"\u003eResistance\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e6000 Î©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e0.1 Î© (â‰¤600 Î©)\u003cbr\u003e1 Î© (â‰¤6000 Î©)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e1% Â±5 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"5\"\u003eCapacitance\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e1000 Î¼F\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e0.1 Î¼F (â‰¤ 100 Î¼F)\u003cbr\u003e1 Î¼ F (â‰¤ 1000 Î¼F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e1% Â±4 digits\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"5\"\u003eMechanical Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBatteries\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e-10 Â°C to +50 Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e-40 Â°C to +60 Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating humidity -\u003cbr\u003enon-condensing (\u0026lt; 10Â°C)\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003eâ‰¤90% RH (at 10 Â°C to 30 Â°C)\u003cbr\u003eâ‰¤75% RH (at 30 Â°C to 40 Â°C)\u003cbr\u003eâ‰¤45% RH (at 40 Â°C to 50 Â°C)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e3000 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e12,000 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e249 x 85 x 45 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e395 g\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eJaw opening\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e34 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFlexible current probe diameter\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e7.5 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFlexible current probe cable length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e1.8 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSafety\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003eIEC 61010-1, Pollution Degree 2\u003cbr\u003eIEC 61010-2-032: CAT III 1000 V \/ CAT IV 600 V\u003cbr\u003eIEC 61010-2-033:CAT III 1000 V \/ CAT IV 600 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eIP rating\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003eIEC 60529: IP30, non-operating\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRadio Frequency Certification FCC ID\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003eT68-FBLE IC:6627A-FBLE\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"5\"\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eInternational\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003eIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2\u003cbr\u003eCISPR 11: Group 1, Class A\u003cbr\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003cbr\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eKorea (KCC)\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003cbr\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTemperature coefficients\u003c\/td\u003e\r\n\u003ctd colspan=\"4\"\u003eAdd 0.1 x specified accuracy for each degree C above 28 Â°C or below 18 Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D4028825009.pdf\"\u003eDatasheet - FLUKE 374FC\u003c\/a\u003e\u003c\/li\u003e\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eClamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS | AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45627368931372,"sku":"FLUKE 374FC","price":14037.18,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/fluke-374fc-5871084.jpg?v=1781042117","url":"https:\/\/xytron.ae\/products\/fluke-374fc","provider":"Xytron","version":"1.0","type":"link"}