{"product_id":"fluke-t5-1000","title":"FLUKE T5-1000","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eElectrical Tester 1000VAC\/DC,100AA\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eElectrical Tester 1000VAC\/DC,100AA\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003eMeasure current up to 100 A without breaking the circuit with OpenJawâ„¢ design. The T5-1000 Electrical Tester is a versatile troubleshooting tool to carry to every job site. Use it to check voltage, continuity, and currentâ€“all with one compact tool.\u003c\/p\u003e\r\n\u003cp\u003eHow to use the T5-1000\u003c\/p\u003e\r\n\u003cp\u003eJust select volts, ohms, or current and the tester does the rest. The electrical tester auto-selects between AC and DC voltage up to 1000 V.\u003c\/p\u003e\r\n\u003cp\u003ePlus, the OpenJawâ„¢ design allows for fast and easy current measurements without needing to make metallic contact, just slide a wire into the open fork. The continuity beeper offers a quick go\/no-go tests, resistance measurements to 1000 Î©.\u003c\/p\u003e\r\n\u003cp\u003eThe electrical tester comes with detachable Slim Reach probe tips so you can easily work in tight spaces. Or hand free work when you use the test lead holder to make the meter an â€œextended handleâ€ for the probe.\u003c\/p\u003e\r\n\u003cp\u003eKey safety features\u003c\/p\u003e\r\n\u003cp\u003eAn integrated protection circuit allows the tester to stay connected to a voltage source longer than a solenoid tester. The T5-1000 Electrical Tester also boasts:\u003c\/p\u003e\r\n\u003cp\u003eA CAT III 1000V, CAT IV 600 V rating\u003c\/p\u003e\r\n\u003cp\u003eWithstands a 10 ft. (3 m) drop.\u003c\/p\u003e\r\n\u003cp\u003eThe T5-1000 has and Auto-off mode to conserve battery life. The unit fits into an optional holster that attaches to a belt and neatly stows test leads.\u003c\/p\u003e\r\n\u003cp\u003eFluke T5-1000 vs T6-1000\u003c\/p\u003e\r\n\u003cp\u003eThe T5-1000 uses the OpenJawâ„¢ design to measure current without metallic contact, just slide the wire in the open fork and the T5 will do the rest. It also measures voltage and continuity with the test leads. The T6-1000 (https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/basic-testers\/fluke-t6-1000) is designed to use FieldSenseâ„¢ technology to display both current and voltage simultaneously.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\u003cul\u003e\r\n\u003cli\u003eOpenJawâ„¢ design: measure current without breaking the circuit\u003c\/li\u003e\r\n\u003cli\u003eTester automatically selects AC or DC voltage, up to 1000 V\u003c\/li\u003e\r\n\u003cli\u003eWork in tight spaces with detachable Slim Reach probe tips\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eJaw opening\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e12.9 mm (0.5 in)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMax wire size\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1\/0 THHN Cable\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCurrent range AC rms\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0 to 100.0 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy AC current (50\/60 Hz)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e3% Â± 3 counts\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAC response\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eAveraging\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVoltage range AC\/DC\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0 to 1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eVoltage accuracy\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAC\u003c\/td\u003e\r\n\u003ctd\u003e1.5% Â± 2 counts\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDC\u003c\/td\u003e\r\n\u003ctd\u003e1% Â± 1 count\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResistance range\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0 to 1000 Î©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eContinuity beeper threshold\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eOn at \u0026lt; 25 Î©, off at \u0026gt; 400 Î©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVolts indicator LED threshold\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eGuaranteed on by 30 V AC\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-10Â°C to 50Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-30Â°C to 60Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"4\"\u003eHumidity (without condensation)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e0% to 95% (5Â°C to 30Â°C);\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e0% to 75% (30Â°C to 40Â°C);\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\"\u003e0% to 45% (40Â°C to 50Â°C)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDust\/water resistance\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2000 meters max\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 x (specified accuracy)\/Â°C (\u0026lt; 18Â°C or\u0026gt; 28Â°C)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMeasurement Category\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eIEC 61010-2-032, IEC61010-2-033: CAT IV 600 V \/ CAT III 1000 V, 100 A ac\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eCSA, TUV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1000 V between any terminal and earth ground\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSize\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e30.5 x 51 x 203 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e300 g\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWarranty\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eTwo-years\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBattery life\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e200 hour zinc chloride, 400 hour alkaline\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBattery type\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2 x AA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eLow battery indicator\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCurrent sensor opening\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e12.9 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D3729061374.pdf\"\u003eDatasheet - FLUKE T5-1000\u003c\/a\u003e\u003c\/li\u003e\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eTester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eElectrical | 1000VAC\/DC,100AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45627366703148,"sku":"FLUKE T5-1000","price":6390.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/fluke-t5-1000-1936770.jpg?v=1781042096","url":"https:\/\/xytron.ae\/fr\/products\/fluke-t5-1000","provider":"Xytron","version":"1.0","type":"link"}