{"product_id":"fluke-87-v","title":"FLUKE 87-V","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eIndustrial Multimeter 1000V 10A AC\/DC (20A for 30 Seconds Max), True RMS, RES:50MÎ©, CAP:9,999 ÂµF, FREQ:200KHz, Duty Cycle:99.9%, Temp:-200.0Â°C~1090Â°C, Conductance:60.00nS, Diode:3V, Resolution:1MV, EN 61010â€“1 to 1000V CATIII, 600V CATIV, 355g\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003e1000V 10A Industrial Multimeter\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003eThe Fluke 87V industrial digital multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment.\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Fluke 87V TRMS Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment even in loud, high energy, and high altitude locations.\u003c\/p\u003e\r\n\u003cp\u003eThis digital multimeter takes the guesswork out of drive system troubleshooting. This electrical multimeter\u003c\/p\u003e\r\n\u003cp\u003eincludes a unique function for accurately measuring noisy at the VFD and at the motor terminals. Special shielding blocks high frequency, high-energy noise generated by large drive systems.\u003c\/p\u003e\r\n\u003cp\u003eThe Fluke 80 Series V of digital multimeters have improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution, and electro-mechanical equipment.\u003c\/p\u003e\r\n\u003cp\u003eOther useful features\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eRugged, high accuracy industrial electrical multimeter to measure current, voltage and frequency on complex variable frequency drive (VFD) signals\u003c\/li\u003e\r\n\u003cli\u003eOffers true-RMS AC voltage and current for measuring non-linear signals\u003c\/li\u003e\r\n\u003cli\u003eCaptures intermittents as short as 250 ÂµS\u003c\/li\u003e\r\n\u003cli\u003eSafety rated CAT III 1000 V, CAT IV 600 V\u003c\/li\u003e\r\n\u003cli\u003eIncludes a built-in thermometer and temperature probe\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eApplications\u003c\/p\u003e\r\n\u003cp\u003eFor Application engineer \/ Plant engineer \/ Industrial electricians (Working with VSDâ€™s) \/ Electrical engineer. In plant automation, Power distribution, Electro-mechanical equipment, Industrial electronics, Setting up \/ repairing, adjustable speed motor drives.\u003c\/p\u003e\r\n\u003cp\u003eIncludes\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\r\n\u003cli\u003eAC175 Alligator Clips\u003c\/li\u003e\r\n\u003cli\u003eHolster\u003c\/li\u003e\r\n\u003cli\u003e9V Battery (Installed)\u003c\/li\u003e\r\n\u003cli\u003e80BK Temperature Probe\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eMaximum voltage\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.05% + 1)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\r\n\u003ctd\u003e10 ÂµV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"4\"\u003eVoltage AC\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eMaximum voltage\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.7% + 2) True RMS\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAC bandwidth\u003c\/td\u003e\r\n\u003ctd\u003e20 kHz with low pass filter; 3 dB @ 1 kHz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eCurrent DC\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eMaximum amps\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.2% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\r\n\u003ctd\u003e0.01 ÂµA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eCurrent AC\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eMaximum amps\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAmps accuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.0% + 2) True RMS\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 ÂµA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eMaximum resistance\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e50 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.2% + 1)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 Î©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eCapacitance\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eMaximum capacitance\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e9,999 ÂµF\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eaccuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\r\n\u003ctd\u003e0.01 nF\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eMaximum frequency\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e200 kHz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.005% + 1)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\r\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eDuty cycle\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eMaximum duty cycle\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e99.9%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.2% per kHz + 0.1%)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTemperature measurement\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-200.0 Â°C to 1090 Â°C\u003cbr\u003e-328.0 Â°F to 1994.0 Â°F\u003cbr\u003eexcluding probe\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e80 BK temperature probe\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-40.0 Â°C to 260 Â°C\u003cbr\u003e-40.0 Â°F to 500 Â°F, 2.2 Â°C or 2% whichever is greater\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eConductance\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eMaximum conductance\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e60.00 nS\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.0% + 10)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum resolution\u003c\/td\u003e\r\n\u003ctd\u003e0.01 nS\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eDiode\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e3 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e1 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(2% + 1)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDuty cycle range\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003eWithin Â±(0.2% per kHz + 0.1%)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eâ€“20 Â°C to + 55 Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eâ€“40 Â°C to + 60 Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0% â€“ 90% (0 Â°C â€“ 35 Â°C)\u003cbr\u003e0% â€“ 70% (35 Â°C â€“ 55 Â°C)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eEN 61010â€“1 to 1000 V CAT III, 600V CAT IV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eCE, CSA, RCM\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSize\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e201 x 98 x 52 mm (with holster)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e355 g\u003cbr\u003e624 g â€“ with holster\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eDisplay\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eDigital\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e6000 counts updates 4\/sec.\u003cbr\u003e19,999 counts in highâ€“resolution mode\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAnalog\u003c\/td\u003e\r\n\u003ctd\u003e32 segments, updates 40\/sec\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFrequency\u003c\/td\u003e\r\n\u003ctd\u003e19,999 counts, updates 3\/sec at \u0026gt; 10 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWarranty\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eLifetime\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBattery Life\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eAlkaline\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e~400 hours typical, without backlight\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eShock\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1 Meter drop per IEC 61010â€“1:2001\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVibration\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003ePer MILâ€“PRFâ€“28800 for a Class 2 instrument\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D2943124913.pdf\"\u003eUser Manual - FLUKE 87-V\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D1031467642.pdf\"\u003eDatasheet - FLUKE 87-V\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eMultimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e1000V | 10A | Industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45627368046636,"sku":"FLUKE 87-V","price":14825.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/fluke-87-v-8160945.jpg?v=1781042107","url":"https:\/\/xytron.ae\/fr\/products\/fluke-87-v","provider":"Xytron","version":"1.0","type":"link"}