{"product_id":"fluke-1587","title":"FLUKE 1587","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eInsulation Tester Combined with a Full-Featured, True RMS Digital Multimeter, 2GÎ© CAT III 1000 V, CAT IV 600V\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eTrue RMS Digital Multimeter\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\u003cul\u003e\r\n\u003cli\u003eSafety first. Keep yourself out of harmâ€™s way by monitoring your test measurements remotely.\u003c\/li\u003e\r\n\u003cli\u003eProve your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.\u003c\/li\u003e\r\n\u003cli\u003eQuickly find problems by saving and comparing measurements over time on a wireless device.\u003c\/li\u003e\r\n\u003cli\u003ePI\/DAR timed ratio tests with TrendItâ„¢ graphs to identify moisture and contaminated insulation problems faster\u003c\/li\u003e\r\n\u003cli\u003eMemory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time\u003c\/li\u003e\r\n\u003cli\u003eTemperature compensation to establish accurate baselines and relevant historical comparisons\u003c\/li\u003e\r\n\u003cli\u003eHistorical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke ConnectÂ® Assets (sold separately)\u003c\/li\u003e\r\n\u003cli\u003eProvides memory storage through Fluke Connect Measurements to eliminate the need to write down results\u003c\/li\u003e\r\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\r\n\u003cli\u003eSupports historical tracking and asset trending of assets to identify degradation over time with Fluke ConnectÂ® Assets (sold separately)\u003c\/li\u003e\r\n\u003cli\u003eIncorporates VFD low-pass filter for accurate variable frequency motor drive measurements\u003c\/li\u003e\r\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\r\n\u003cli\u003eMeasures ac\/dc voltage, dc millivolts, ac\/dc milliamps, resistance, and continuity\u003c\/li\u003e\r\n\u003cli\u003eIncludes capacitance, diode test, temperature, min\/max, frequency measurements and insulation test smoothing reading\u003c\/li\u003e\r\n\u003cli\u003eAutomatically powers off to save battery power\u003c\/li\u003e\r\n\u003cli\u003eComes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003eAC voltage measurement\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003eRange\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e600.0 mV\u003c\/td\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 5000 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(2% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e6.000 V\u003c\/td\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.001 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 5000 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(2% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e60.00 V\u003c\/td\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.01 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 5000 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(2% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e600.0 V\u003c\/td\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 5000 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(2% + 3)Â¹\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e1000 V\u003c\/td\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e1 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(2% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 5000 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(2% + 3)Â¹\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"small\" colspan=\"3\"\u003eÂ¹ 1 kHz bandwidth\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eLow-Pass Filter VoltageÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003eRange\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e600.0 mV\u003c\/td\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 400 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e6.000 V\u003c\/td\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.001 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 400 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e60.00 V\u003c\/td\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.01 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 400 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e600.0 V\u003c\/td\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 400 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e1000 V\u003c\/td\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e1 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(2% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 400 Hz Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eDC Voltage Measurement\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eAccuracy Â±(% of Rdg + Counts)\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e6.000 V dc\u003c\/td\u003e\r\n\u003ctd\u003e0.001 V\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.09% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e60.00 V dc\u003c\/td\u003e\r\n\u003ctd\u003e0.01 V\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.09% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e600.0 V dc\u003c\/td\u003e\r\n\u003ctd\u003e0.1 V\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.09% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e1000 V dc\u003c\/td\u003e\r\n\u003ctd\u003e1 V\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.09% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eInput impedanceÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e10 MÎ© (nominal), \u0026lt;100 pF\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eNormal mode rejection ratioÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e\u0026gt;60 dB @ 50 Hz or 60 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCommon mode rejection ratioÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e\u0026gt;120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eAccuracies apply to Â± 100% of range\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eDC Millivolts Measurement\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eAccuracy Â±(% of Rdg + Counts)\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e600.0 mVdc\u003c\/td\u003e\r\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.1% + 1)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eDC and AC Current Measurement\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003eAC 45 Hz to 1000 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e400 mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy Â±(% of Rdg+Counts)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eÂ±(1.5% + 2)Â¹\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e60 mAÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.01 mAÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy Â±(% of Rdg+Counts)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eÂ±(1.5% + 2)Â¹\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eDC\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e400 mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy Â±(% of Rdg+Counts)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eÂ±(0.2% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e60 mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.01 mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy Â±(% of Rdg+Counts)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eÂ±(0.2% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOverload\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e600 mA for 2 minutes maximum\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFuse protection for mA input\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.44 mA, 1000 V, IR 10 kA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAC conversion\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eInputs are ac-coupled and calibrated to the rms value of sine wave input\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eConversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor â‰¤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eÂ¹ 1 kHz bandwidth\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eOhms Measurement\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eAccuracy +(% of Rdg+Counts)Â¹\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e600.0 Î©\u003c\/td\u003e\r\n\u003ctd\u003e0.1 Î©\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.9% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e6.000 kÎ©\u003c\/td\u003e\r\n\u003ctd\u003e0.001 kÎ©\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.9% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e60.00 kÎ©\u003c\/td\u003e\r\n\u003ctd\u003e0.01 kÎ©\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.9% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e600.0 kÎ©\u003c\/td\u003e\r\n\u003ctd\u003e0.1 KÎ©\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.9% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e6.000 MÎ©\u003c\/td\u003e\r\n\u003ctd\u003e0.001 MÎ©\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.9% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e50.0 MÎ© Â²\u003c\/td\u003e\r\n\u003ctd\u003e0.01 MÎ©\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.5% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOverload protectionÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1000 V rms or dc\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOpen circuit test voltageÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e\u0026lt;8.0 V dc\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eShort circuit currentÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e\u0026lt;1.1 mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eÂ¹ Accuracies apply from 0% to 100% of range\u003cbr\u003eÂ² Up to 80% relative humidity\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eDiode Test\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDiode test indication\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eDisplay voltage drop: 0.6 V at1.0 mA nominal test current:\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eÂ±(2% + 3)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eContinuity Test\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eContinuity indication\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eContinuous audible tone for testresistance below 25 Î© and off above 100 Î©. Maximum Reading; 1000 Î©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e\u0026lt;8.0 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1.0 mA typical\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOverload protection\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1000 V rms\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResponse time\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e\u0026gt;1 m sec\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eFrequency Measurement\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRange\u003c\/td\u003e\r\n\u003ctd\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003eAccuracy Â±(% of Rdg+Counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e99.99 HzÂ \u003c\/td\u003e\r\n\u003ctd\u003e0.01 HzÂ \u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.1% + 1)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e999.9 HzÂ \u003c\/td\u003e\r\n\u003ctd\u003e0.1 HzÂ \u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.1% + 1)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e9.999 kHzÂ \u003c\/td\u003e\r\n\u003ctd\u003e0.001 kHzÂ \u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.1% + 1)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e99.99 kHzÂ \u003c\/td\u003e\r\n\u003ctd\u003e0.01 kHzÂ \u003c\/td\u003e\r\n\u003ctd\u003eÂ±(0.1% + 1)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eFrequency Counter Sensitivity\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e600.0 mV acÂ \u003c\/td\u003e\r\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)Â¹ Â 5 Hz to 20 kHzÂ \u003c\/td\u003e\r\n\u003ctd\u003e100.0 mVÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)Â¹Â  20 kHz to 100 kHz\u003c\/td\u003e\r\n\u003ctd\u003e150.0 mVÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDC Trigger LevelsÂ¹ to 20 kHzÂ²\u003c\/td\u003e\r\n\u003ctd\u003eNA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e6.0 VÂ \u003c\/td\u003e\r\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)Â¹ Â 5 Hz to 20 kHzÂ \u003c\/td\u003e\r\n\u003ctd\u003e1.0 VÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)Â¹Â  20 kHz to 100 kHz\u003c\/td\u003e\r\n\u003ctd\u003e1.5 VÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDC Trigger LevelsÂ¹ to 20 kHzÂ²\u003c\/td\u003e\r\n\u003ctd\u003e-400.0 mV and 2.5 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e60.0 VÂ \u003c\/td\u003e\r\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)Â¹ Â 5 Hz to 20 kHzÂ \u003c\/td\u003e\r\n\u003ctd\u003e10.0 VÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)Â¹Â  20 kHz to 100 kHz\u003c\/td\u003e\r\n\u003ctd\u003e36.0 VÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDC Trigger LevelsÂ¹ to 20 kHzÂ²\u003c\/td\u003e\r\n\u003ctd\u003e1.2 V and 4.0 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e600.0 VÂ \u003c\/td\u003e\r\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)Â¹ Â 5 Hz to 20 kHzÂ \u003c\/td\u003e\r\n\u003ctd\u003e100.0 VÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)Â¹Â  20 kHz to 100 kHz\u003c\/td\u003e\r\n\u003ctd\u003e-\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDC Trigger LevelsÂ¹ to 20 kHzÂ²\u003c\/td\u003e\r\n\u003ctd\u003e12.0 V and 40.0 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003e1000.0 VÂ \u003c\/td\u003e\r\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)Â¹ Â 5 Hz to 20 kHzÂ \u003c\/td\u003e\r\n\u003ctd\u003e300.0 VÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)Â¹Â  20 kHz to 100 kHz\u003c\/td\u003e\r\n\u003ctd\u003e-\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDC Trigger LevelsÂ¹ to 20 kHzÂ²\u003c\/td\u003e\r\n\u003ctd\u003e12.0 V and 40.0 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eÂ¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy\u003cbr\u003eÂ² Usable to 100 kHz with full scale input\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eCapacitance\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRangeÂ \u003c\/td\u003e\r\n\u003ctd\u003eResolutionÂ \u003c\/td\u003e\r\n\u003ctd\u003eAccuracy Â±(% of Rdg+Counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e1000 nFÂ \u003c\/td\u003e\r\n\u003ctd\u003e1 nF\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.2% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e10.00 Î¼FÂ \u003c\/td\u003e\r\n\u003ctd\u003e0.01 Î¼F\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.2% + 2)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e100.0 Î¼FÂ \u003c\/td\u003e\r\n\u003ctd\u003e0.1 Î¼F\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.2% Â±90 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003e9999 Î¼FÂ \u003c\/td\u003e\r\n\u003ctd\u003e1 Î¼F\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.2% Â±90 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eTemperature Measurement\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRangeÂ \u003c\/td\u003e\r\n\u003ctd\u003eResolutionÂ \u003c\/td\u003e\r\n\u003ctd\u003eAccuracy Â±(% of Rdg+Counts)Â¹\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e-40 Â° C to 537 Â° CÂ \u003c\/td\u003e\r\n\u003ctd\u003e0.1 Â°CÂ \u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1% + 10 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e-40 Â° F to 998 Â° FÂ \u003c\/td\u003e\r\n\u003ctd\u003e0.1 Â°FÂ \u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1% + 18 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eÂ¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.01 MÎ© to 2 GÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTest voltages\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e50, 100, 250, 500, 1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e+20%, -0%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eShort-circuit test current\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt;0.5 second for C = 1 Î¼F or less\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eLive circuit detection\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 Î¼F load\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eOutput Voltage\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"8\"\u003e50 V (0% to +20%)\u003c\/td\u003e\r\n\u003ctd\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e0.01 to 6.00 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.01 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 50 kÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(3% + 5 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e6.0 to 50.0 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 50 kÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(3% + 5 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"12\"\u003e100 V (0% to +20%)\u003c\/td\u003e\r\n\u003ctd\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e0.01 to 6.00 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.01 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 100 kÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(3% + 5 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e6.0 to 60.0 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 100 kÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(3% + 5 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e60 to 100 MÎ©Â \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 100 kÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(3% + 5 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"8\"\u003e250 V (0% to +20%)\u003c\/td\u003e\r\n\u003ctd\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e0.1 to 60.0 MÎ©Â \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 250 kÎ©Â \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.5% + 5 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e60 to 250 MÎ©Â \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 250 kÎ©Â \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.5% + 5 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"8\"\u003e500 V (0% to +20%)\u003c\/td\u003e\r\n\u003ctd\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e0.1 to 60.0 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 500 kÎ©Â \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.5% + 5 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e60 to 500 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 500 kÎ©Â \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.5% + 5 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"12\"\u003e1000 V (0% to +20%)\u003c\/td\u003e\r\n\u003ctd\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e0.1 to 60.0 MÎ©Â \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e0.1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.5% + 5 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e60 to 600 MÎ©Â \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(1.5% + 5 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\r\n\u003ctd\u003e0.6 to 2.0 GÎ©Â \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\r\n\u003ctd\u003e100 MÎ©Â \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\r\n\u003ctd\u003e1 mA @ 1 MÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eResistance accuracy Â±(% of Rdg + Counts)\u003c\/td\u003e\r\n\u003ctd\u003eÂ±(10% + 3 counts)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum voltage applied to any terminal and common\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-40 Â°C to 60 Â°C (-40 Â°F to 140 Â°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-20 Â°C to 55 Â°C (-4 Â°F to 131 Â°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per Â°C for temperatures \u0026lt;18 Â°C or \u0026gt;28 Â°C (\u0026lt;64 Â°F or \u0026gt;82 Â°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eNoncondensing\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10 Â°C to 30 Â°C (50 Â°F to 86 Â°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30 Â°C to 40 Â°C (86 Â°F to 104 Â°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40 Â°C to 55 Â°C (104 Â°F to 131 Â°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVibration\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRadio frequency communication\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2.4 GHz ISM Band\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRadio frequency certification\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eFCC: T68-FBLE, IC: 6627A-FBLE\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eElectromagnetic CompatibilityÂ \u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"4\"\u003eInternational\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eIEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.Â  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eEmissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and\/or test probes are connected.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eKorea (KCC)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eEnclosure protection\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP40 (non-operating)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eSafety\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eIEC 61010-1\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003ePollution Degree 2\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eIEC 61010-2-033\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBatteriesÂ \u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eFour AA batteries (IEC LR6)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBattery life\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eMeter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MÎ© with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\r\n\u003ctd\u003eOperating\u003c\/td\u003e\r\n\u003ctd\u003e2000 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\"\u003eStorage\u003c\/td\u003e\r\n\u003ctd\u003e12,000 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e110% of range except for capacitance which is 100%\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFrequency overload protection\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e\u0026lt;107 V Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eFuse protection for mA input\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.44A, 1000 V, IR 10 kA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D0323025788.pdf\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D1956693220.pdf\"\u003eSpecifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D1211472023.pdf\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D1929964742.pdf\"\u003eFeatures\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeywords\u003c\/td\u003e\n\u003ctd\u003efluke,  fluke 1587,  Digital Multimeter,  True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eMultimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eTrue RMS | Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45627369259052,"sku":"FLUKE 1587","price":26925.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/fluke-1587-4377926.jpg?v=1781042124","url":"https:\/\/xytron.ae\/fr\/products\/fluke-1587","provider":"Xytron","version":"1.0","type":"link"}