{"product_id":"hkd-trigge-delay-timer-24h-5-30v","title":"HKD TRIGGE DELAY TIMER 24H 5-30V","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eTrigger Cycle Timer Delay Switch 5-30v Relay Switch Module 24H Timing Control\u003c\/span\u003e\u003c\/div\u003e\n\u003ch1\u003e24H Time Switch 5-30V\u003c\/h1\u003e\n\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eWide voltage power supply 5.0V ~ 60V;\u003c\/li\u003e\n\u003cli\u003eA mode can be set for multiple time periods, can reach 5 time periods;\u003c\/li\u003e\n\u003cli\u003eWith a buzzer alarm function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMode Introduction:\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eOPE: relay closing time point, CLE: relay off time point\u003c\/li\u003e\n\u003cli\u003eTime period: PE-1 ~ PE-5 5 time periods (OPE to CLE is a time period)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFunction Shielding\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eP-1: The relay closes or outputs pulses every day to the OPE time point, and the relay turns off or outputs pulses to the CLE time point.\u003c\/li\u003e\n\u003cli\u003eP-2: set the day, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay disconnect \/ or output pulse\u003c\/li\u003e\n\u003cli\u003eP-3: set the date of the month, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay is off or output pulse\u003c\/li\u003e\n\u003cli\u003eP-4: Set the date 1 to date 2, start every day at the OPE time point, end to the CLE time point, relay action or output pulse\u003c\/li\u003e\n\u003cli\u003eP-5: As with P-4, only the month can not be set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHow to set the time?\u003c\/p\u003e\n\u003cp\u003eIn the time to run the interface, press the DOWN button for a while:\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eStep 1: Select the time period: PE-1 ~ PE-5 Press UP and DOWN to select;\u003c\/li\u003e\n\u003cli\u003eStep 2: Press the SET key to select the mode: P-1 ~ P-5 (Set this time period to the corresponding mode) by pressing the UP and DOWN keys. (\"----\" means to block this time period)\u003c\/li\u003e\n\u003cli\u003eNote: Each time period can be repeated from the \"----\", P-1 ~ P-5 one of the optional; For example,you can let five time periods at the same time work in the P-1 mode, or let Time period 1 work in P-1 mode, time period 2 work in P-2 mode and so on.\u003c\/li\u003e\n\u003cli\u003eStep 3: After the mode selection is finished, press the SET key to enter the time period setting interface, set the interface in the time period, press the SET key to switch the parameter, \"OPE\" start time point, \"CLE\" end point, \"dAE\" date information;\u003c\/li\u003e\n\u003cli\u003eStep 4: After setting the parameters to exit the settings, press the SET button for 2 seconds to release, automatically check whether the parameter settings are legal, legal to save the parameters, return to the time to run the interface; if the parameter is wrong, \"ERR\" reminder (for example, stop time or Date \u0026lt;= start time or date), return to the parameter setting interface;\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach \"time period\" can be set individually\u003c\/p\u003e\n\u003cp\u003eIn the specific parameter setting interface (after the second step), press the STOP button to switch the output mode:\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eOUT1: Start time point turns on the relay, the end time is off the relay\u003c\/li\u003e\n\u003cli\u003eOUT2: Outputs 1S pulse to start or end time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn the specific parameter setting interface (after the second step), press the STOP button for a while to switch the ringing mode:\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eBLL0: Ring disable\u003c\/li\u003e\n\u003cli\u003eBLL1: Ring enable\u003c\/li\u003e\n\u003cli\u003eNote: When the bell rings, press any button to stop the ring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSTOP Key Function Expansion:\u003c\/p\u003e\n\u003cp\u003eRelay Enable Mode:\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eON: enable relay on;\u003c\/li\u003e\n\u003cli\u003eOFF: Do not turn on the relay, it is always off;\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePress the STOP button on the time display interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is the emergency stop function, press once to close the closed relay)\u003c\/p\u003e\n\u003cp\u003eAfter the relay is disabled, the product can be used as an alarm clock.\u003c\/p\u003e\n\u003cp\u003eSleep mode:\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eC-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation;\u003c\/li\u003e\n\u003cli\u003eO-d normal mode: digital tube is always open display;\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePress the STOP button for a while after 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.\u003c\/p\u003e\n\u003cp\u003ePackage include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 * Time Controller Relay Switch Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003col\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D0701166627.pdf\"\u003eDatasheet - TRIGGE DELAY TIMER 24H 5-30V\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\" cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eTime Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e24H | 5-30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Communica","offers":[{"title":"Default Title","offer_id":44756988166188,"sku":"HKD TRIGGE DELAY TIMER 24H 5-30V","price":113.04,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/hkd-trigge-delay-timer-24h-5-30v-203911.jpg?v=1757347549","url":"https:\/\/xytron.ae\/de\/products\/hkd-trigge-delay-timer-24h-5-30v","provider":"Xytron","version":"1.0","type":"link"}