{"product_id":"hkd-buck-boost-solar-0-5-30v-4a","title":"HKD BUCK\/BOOST\/SOLAR 0.5-30V 4A","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eZK-4KX CNC DC DC Buck Boost Converter CC CV 0.5-30V 4A Power Module Adjustable Regulated Power Supply for Solar Battery Charging. CC CV 0.5-30V 4A\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eCNC DC DC Buck Boost Converter\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\u003cul\u003e\r\n\u003cli\u003eLCD can display input\/output voltage, output current\/output power\/output capacity\/output time;\u003c\/li\u003e\r\n\u003cli\u003eCNC adjustment, accurate and fast, can boost and lower voltage, output voltage can be adjusted at will from 0.5-30v, limit current 0-4a can be adjusted at will;\u003c\/li\u003e\r\n\u003cli\u003eAnti-reverse connection protection of input end, which will not burn out;\u003c\/li\u003e\r\n\u003cli\u003eAnti-reverse irrigation at the output end, no additional anti-reverse irrigation diode is needed to charge the battery;\u003c\/li\u003e\r\n\u003cli\u003eThe module can be set to open\/close by default;\u003c\/li\u003e\r\n\u003cli\u003eMultiple software protection mechanisms are available, and the protection threshold is adjustable.When the working parameters of the module exceed the protection threshold, the output will be automatically closed.\u003c\/li\u003e\r\n\u003cli\u003eOutput ripple is small and PI filter is available;\u003c\/li\u003e\r\n\u003cli\u003eThicken radiator fins.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cul\u003e\r\n\u003cli\u003eInput voltage: 5.0-30v\u003c\/li\u003e\r\n\u003cli\u003eOutput voltage: 0.5-30v\u003c\/li\u003e\r\n\u003cli\u003eOutput current: can work stably at 3A for a long time, and can reach 4A under enhanced heat dissipation\u003c\/li\u003e\r\n\u003cli\u003eOutput power: natural heat dissipation 35W, strengthen heat dissipation 50W\u003c\/li\u003e\r\n\u003cli\u003eVoltage display resolution: 0.01V\u003c\/li\u003e\r\n\u003cli\u003eCurrent display resolution: 0.001A\u003c\/li\u003e\r\n\u003cli\u003eConversion efficiency: about 88%\u003c\/li\u003e\r\n\u003cli\u003eSoft start: yes (with high power and load module may fail when starting)\u003c\/li\u003e\r\n\u003cli\u003eProtection mechanism:\u003c\/li\u003e\r\n\u003cli\u003eInput anti-reverse connection;\u003c\/li\u003e\r\n\u003cli\u003eOutput anti-reverse irrigation;\u003c\/li\u003e\r\n\u003cli\u003eInput undervoltage protection (4.8-30V adjustable, default 4.8v)\u003c\/li\u003e\r\n\u003cli\u003eOutput overvoltage protection (0.5-31V adjustable, default 31V)\u003c\/li\u003e\r\n\u003cli\u003eOutput overcurrent protection 0-4.1a (adjustable, default 4.1a)\u003c\/li\u003e\r\n\u003cli\u003eOverpower protection (0-50w adjustable, default 50W)\u003c\/li\u003e\r\n\u003cli\u003eOvertemperature protection (80-110??adjustable, default 110??\u003c\/li\u003e\r\n\u003cli\u003eTimeout protection (0-100h adjustable, off by default)\u003c\/li\u003e\r\n\u003cli\u003eSuper capacity protection (0-60ah adjustable, off by default)\u003c\/li\u003e\r\n\u003cli\u003eOperating frequency: 180KHZ \u003c\/li\u003e\r\n\u003cli\u003eDimensions: 79mmx43mmx26mm\u003cbr\u003e \u003cbr\u003e Method of Use:\u003cbr\u003e \u003c\/li\u003e\r\n\u003cli\u003eSwitch display parameters -- in the normal interface, press SW to switch the display below the display screen, and switch the display content between current A power W capacity Ah time h.Long press SW button to switch the uplink display on the display screen and switch the display content between input voltage IN output voltage OUT.\u003cbr\u003e Set output voltage -- press U\/I button in the normal interface to enter the interface of setting voltage constant current.It can be seen that a certain digit of the output voltage value is flashing. Rotate the encoder left and right to adjust the major and minor.Short press the rotary encoder to choose which bit of output voltage to set.After setting, press U\/I button 2 times to return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSet constant current value (that is, the maximum current value allowed to output by the module) -- press U\/I button in the normal interface to enter the setting voltage constant current interface.Then press U\/I button and switch to setting constant current value. You can see a bit of the setting constant current value flashing. Rotate the rotary encoder left and right to adjust the major and minor.Short press the rotary encoder to choose which bit to set the constant current value.After setting, press U\/I to exit the setting voltage constant current interface and return to the normal interface.Or automatically return to the normal interface after stopping operation for 10s.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSet the default on\/off state of module power-on -- long press U\/I in the normal interface to enter the parameter setting interface.You can see that it shows \"\"OPEN OFF\"\" or \"\"OPEN ON\"\". \"\"OPEN OFF\"\" means the output is turned OFF by default when power is ON, and \"\"OPEN ON\"\" means the output is turned ON by default when power is ON.Long press rotate encoder to switch two states.After setting, long press U\/I to return to the normal interface.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSetting of protection parameters on state and threshold -- long press U\/I to enter the parameter setting interface in the normal interface.Press SW until the protection you want appears.LUP -- undervoltage protection threshold;OUP -- overvoltage protection threshold;OCP -- overcurrent protection threshold;OPP -- over power protection threshold;OAP -- ultra-capacity protection threshold;OHP timeout protection threshold;OTP -- overtemperature protection threshold.Short press rotate encoder to select which bit you want to set the protection parameter.Long press the rotary encoder to set the protection parameters on or off (only timeout protection and supercapacity protection can be set to turn on\/off, and other protection parameters are turned on by default.).Rotate the encoder left and right to make the parameters bigger and smaller.After setting, long press U\/I to return to the normal interface.\u003c\/li\u003e\r\n\u003cli\u003eCalibration voltage and current -- press U\/I button to enter the parameter setting interface under normal interface.Press SW until a parameter interface with CAL appears.The calibration input voltage interface with the symbol CAL+IN+V;The calibration output voltage interface with the symbol CAL+OUT+V;The calibration output current interface with the symbol CAL+OUT+A.Rotate the encoder left and right to adjust the size of parameters.After the adjustment is completed, long press the rotary encoder to confirm the adjustment is completed, and the parameter value is no longer flashing.Long press U\/I to return to the normal interface. \u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eNote: in order to ensure the accuracy of calibration, calibration voltage -- above 12V can only be started;Calibration current - start calibration only when the current is above 1A.\u003cbr\u003e \u003cbr\u003e Tips:\u003cbr\u003e \u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eShort connection between input IN and output OUT of the module is forbidden, or the constant current function will fail.\u003c\/li\u003e\r\n\u003cli\u003ePlease ensure that the power moment of the power supply exceeds the required power of the output load!\u003c\/li\u003e\r\n\u003cli\u003eIf the module wants to output with full load, the input voltage should be above 8V. When the input voltage is 5V, the output power is about 15W.The maximum module current value is 4A, subject to the maximum output power, such as 17V, the current should not be greater than 2A.\u003c\/li\u003e\r\n\u003cli\u003eWhen this module is used over 3A and 35W, please strengthen heat dissipation!!!\u003c\/li\u003e\r\n\u003cli\u003eThe module has input undervoltage protection function, which is about 4.8v by default (it can be set), and the output will be automatically disconnected after the value is lower than this value (note that the voltage at the module port is lower than the undervoltage protection threshold, and when the input current is relatively large, do not ignore the partial voltage on the input wire).\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D3002734940.pdf\"\u003eDatasheet - HKD BUCKBOOSTSOLAR 0.5-30V 4A\u003c\/a\u003e\u003c\/li\u003e\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eBoost Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eCNC | DC DC | Buck\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Communica","offers":[{"title":"Default Title","offer_id":45625495552044,"sku":"HKD BUCK\/BOOST\/SOLAR 0.5-30V 4A","price":226.09,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/331efd74520c67f84c8ceb32202460e9.jpg?v=1781022922","url":"https:\/\/xytron.ae\/de\/products\/hkd-buck-boost-solar-0-5-30v-4a","provider":"Xytron","version":"1.0","type":"link"}