{"product_id":"fluke-1630-2fc","title":"FLUKE 1630-2FC","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eStakeless Earth Ground Loop and AC Leakage Current Clamp for Fast, Safe Indoor\/Outdoor Earth Ground Resistance and AC Leakage Current Tests\u003c\/span\u003e\u003c\/div\u003e\n\u003ch1\u003eEarth Ground Loop and AC Leakage Current Clamp\u003c\/h1\u003e\n\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003eThe 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes.\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ch3\u003eEarth ground ac leakage current measurement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIdentify ac leakage currents without disconnecting the earth ground stake from the grounding system–ideal for system troubleshooting.\u003c\/li\u003e\n\u003cli\u003eRugged heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogging measurements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe earth ground clamp saves time by automatically recording data at pre-set intervals\u003c\/li\u003e\n\u003cli\u003eSaves up to 32,760 measurements in memory at the set logging interval.\u003c\/li\u003e\n\u003cli\u003eSaves time by recording and storing measured values.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAlarm threshold\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUser-defined high\/low alarm limits, for rapid measurement evaluation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBand-pass filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable band-pass filter function removes unwanted noise from the ac leakage current measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFluke Connect® Wireless System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 1630-2 FC supports the Fluke Connect Wireless System connects the clamp with an app on your smartphone or tablet (may not be available in all regions).\u003c\/li\u003e\n\u003cli\u003eYou can save these measurements, and images to Fluke Connect Cloud storage and share with your team.\u003c\/li\u003e\n\u003cli\u003eMaximize uptime and make confident maintenance decisions with data you can trust and trace.\u003c\/li\u003e\n\u003cli\u003eAccess baseline, historical and current measurements by asset.\u003c\/li\u003e\n\u003cli\u003eShare your measurement data using ShareLive™ video calls and emails.\u003c\/li\u003e\n\u003cli\u003eThe 1630-2 FC is part of a growing system of connected test tools and equipment maintenance software. Visit the website to learn more about the Fluke Connect system. Find out more at \u003ca href=\"https:\/\/connect.fluke.com\/en\/stores\/home\" target=\"_blank\"\u003eflukeconnect.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage to earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAA alkaline IEC\/EN LR6 (x4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMore than 15 hours*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003csmall\u003e* In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e40 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 60529: IP30 with jaw closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLCD\u003c\/td\u003e\n\u003ctd\u003eDigital reading\u003c\/td\u003e\n\u003ctd\u003e9999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefresh rate\u003c\/td\u003e\n\u003ctd\u003e4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to + 50 °C\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20 °C to + 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNon condensing (\u0026lt;10 °C) (\u0026lt; 50 °F)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e≤90% RH (at 10 °C to 30 °C [50 °F to 86 °F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e≤75% RH (at 30 °C to 40 °C [86 °F to 104 °F]) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e≤45% RH (at 40 °C to 50 °C [104 °F to 122 °F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e(Non condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m (6561 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12 000 m (39,370 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e23 °C ±5 °C (73 °F ±9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.15% x (specified accuracy)\/ °C (\u0026lt;18 °C or \u0026gt;28 °C [\u0026lt;64.4 °F or \u0026gt;82.4 °F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload indication\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData logging capacity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMinimum of 32,760 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData logging interval\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 second to 59 minutes and 59 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eDisplay reading specification with standard loop resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput (Ω)\u003c\/td\u003e\n\u003ctd\u003eMinimum\u003c\/td\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.474\u003c\/td\u003e\n\u003ctd\u003e0.417\u003c\/td\u003e\n\u003ctd\u003e0.531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e0.443\u003c\/td\u003e\n\u003ctd\u003e0.558\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9.55\u003c\/td\u003e\n\u003ctd\u003e10.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003ctd\u003e104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSafety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61010-1: Pollution Degree 2 IEC\/EN 61557-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61010-2-032: CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent clamp for leakage current measurements\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61557-13: Class 2, ≤30 A\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance to earth\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61557-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffectiveness of thepProtective measures\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61557-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eElectromagnetic compatibility (EMC)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eInternational\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326-1: Portable Electromagnetic Environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCISPR 11: Group 1, Class B, IEC\/EN 61326-2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd\u003eClass A equipment (Industrial Broadcast \u0026amp; Communications Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eWireless Radio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2412 MHz to 2462 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;10 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio frequency certification\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFCC ID:T68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e40 mm (1.57 in) approximately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e880g (31 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOne year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEarth Ground Loop Resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e  ± (% of reading + Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.025 Ω to 0.249 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% + 0.02 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.250 Ω to 0.999 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% + 0.05 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.000 Ω to 9.999 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% + 0.10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.00 Ω to 49.99 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% + 0.30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50.00 Ω to 99.99 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% + 0.50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100.0 Ω to 199.9 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.0% + 1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω to 399.9 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0% + 5.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400 Ω to 599 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10.0% + 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600 Ω to 1500 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20.00%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003csmall\u003e\u003csup\u003e1\u003c\/sup\u003e  Loop resistance with no inductance, conductor centered and perpendicular to jaw\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEarth ground leakage current mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAutorange 50\/60 Hz, True rms, crest factor CF ≤3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e  ± (% of reading + mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.200 mA to 3.999 mA\u003c\/td\u003e\n\u003ctd\u003e1 μA\u003c\/td\u003e\n\u003ctd\u003e2.0% + 0.05 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.00 mA to 39.99 mA\u003c\/td\u003e\n\u003ctd\u003e10 μA\u003c\/td\u003e\n\u003ctd\u003e2.0% + 0.03 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40.0 mA to 399.9 mA\u003c\/td\u003e\n\u003ctd\u003e100 μA\u003c\/td\u003e\n\u003ctd\u003e2.0% + 0.3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.400 A to 3.999 A\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.00 A to 39.99 A\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003ctd\u003e2.0% + 30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003csmall\u003e\u003csup\u003e1\u003c\/sup\u003e Applies to signal frequency\u003c\/small\u003e\n\u003cul\u003e\n\u003cli\u003e\u003csmall\u003e40 Hz to 1 kHz with filter set to OFF\u003c\/small\u003e\u003c\/li\u003e\n\u003cli\u003e\u003csmall\u003e40 Hz to 70 Hz with filter se to ON\u003c\/small\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003col\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D3430457695.pdf\"\u003eUser Manual - FLUKE 1630-2FC\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\" cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eCurrent Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eEarth Ground Loop | AC Leakage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":44756669235244,"sku":"FLUKE 1630-2FC","price":55590.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/fluke-1630-2fc-224300.jpg?v=1757344997","url":"https:\/\/xytron.ae\/de\/products\/fluke-1630-2fc","provider":"Xytron","version":"1.0","type":"link"}