{"product_id":"6es7331-7tf01-0ab0","title":"6ES7331-7TF01-0AB0","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eSIMATIC DP, HART Analog Input SM 331, 8 AI, 0\/4 - 20mA HART, for ET200M\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eAnalog Input Module with HART\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003eSupply voltage\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eLoad voltage L+\u003c\/li\u003e\r\n\u003cli\u003eRated value (DC) : 24 V\u003c\/li\u003e\r\n\u003cli\u003eReverse polarity protection : Yes\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eInput current\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003efrom load voltage L+ (without load), max. : 20 mA\u003c\/li\u003e\r\n\u003cli\u003efrom backplane bus 5 V DC, max. : 120 mA\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eOutput voltage\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003ePower supply to the transmitters\u003cbr\u003e\r\n\u003cul\u003e\r\n\u003cli\u003epresent : Yes\u003c\/li\u003e\r\n\u003cli\u003eRated value (DC) : 24 V\u003c\/li\u003e\r\n\u003cli\u003eshort-circuit proof : Yes\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003ePower losses\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003ePower loss, typ. : 1.5 W\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eAnalog inputs\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eNumber of analog inputs : 8\u003c\/li\u003e\r\n\u003cli\u003epermissible input current for current input (destruction limit), max. : 40 mA\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eInput ranges\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eVoltage : No\u003c\/li\u003e\r\n\u003cli\u003eCurrent : Yes\u003c\/li\u003e\r\n\u003cli\u003eThermocouple : No\u003c\/li\u003e\r\n\u003cli\u003eResistance thermometer : No\u003c\/li\u003e\r\n\u003cli\u003eResistance : No\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eInput ranges (rated values), currents\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e0 to 20 mA : Yes\u003c\/li\u003e\r\n\u003cli\u003eInput resistance (0 to 20 mA) : 240 Ω\u003c\/li\u003e\r\n\u003cli\u003eInput resistance (-20 to +20 mA) : 240 Ω\u003c\/li\u003e\r\n\u003cli\u003eInput resistance (4 to 20 mA) : 240 Ω\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eCable length\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCable length, shielded, max. : 800 m\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eAnalog value creation\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eMeasurement principle : Sigma Delta\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eIntegrations and conversion time\/ resolution per channel\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eResolution with overrange (bit including sign), max. : 16 bit\u003c\/li\u003e\r\n\u003cli\u003eIntegration time, parameterizable : Yes\u003c\/li\u003e\r\n\u003cli\u003eIntegration time, ms : 20 ms@50 Hz\/16.6 ms@60 Hz\/100 ms@100 Hz\u003c\/li\u003e\r\n\u003cli\u003eBasic conversion time, including integration time, ms : 65ms@50Hz \/ 55ms@60Hz \/ 305ms@100Hz\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eEncoder\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eConnection of signal encoders\u003cbr\u003e\r\n\u003cul\u003e\r\n\u003cli\u003efor current measurement as 2-wire transducer : Yes\u003c\/li\u003e\r\n\u003cli\u003efor current measurement as 4-wire transducer : Yes\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eErrors\/accuracies\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eLinearity error (relative to input area) : +\/- 0.01 %\u003c\/li\u003e\r\n\u003cli\u003eTemperature error (relative to input area) : +\/- 0.001 %\/K\u003c\/li\u003e\r\n\u003cli\u003eCrosstalk between the inputs, min. : 70 dB\u003c\/li\u003e\r\n\u003cli\u003eRepeat accuracy in settled status at 25 °C (relative to input area) : +\/- 0.1 %\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eOperational limit in overall temperature range\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCurrent, relative to input area : +\/- 0,15 %\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eBasic error limit (operational limit at 25 °C)\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eCurrent, relative to input area : +\/- 0,1 %\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eInterference voltage suppression for f = n x (f1 +\/- 1 %), f1 = interference frequency\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSeries mode interference (peak value of interference \u0026lt; rated value of input range), min. : 40 dB\u003c\/li\u003e\r\n\u003cli\u003eCommon mode interference, min. : 100 dB\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eIsochronous mode\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eIsochronous operation (application synchronized up to terminal) : No\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D2687815058.pdf\"\u003eDatasheet - 6ES7331-7TF01-0AB0\u003c\/a\u003e\u003c\/li\u003e\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHART | ET200M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":45625520062508,"sku":"6ES7331-7TF01-0AB0","price":35495.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/6es7331-7tf01-0ab0-855922.jpg?v=1781023257","url":"https:\/\/xytron.ae\/de\/products\/6es7331-7tf01-0ab0","provider":"Xytron","version":"1.0","type":"link"}