{"product_id":"usr-m100-eau-remot-io-edg-gatewy","title":"USR M100-EAU REMOT IO EDG GATEWY","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eExpandable Remote IO Edge Gateway. Enables Edge Connectivity in the IIOT ERA. Ethernet and LTE\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eExpandable Remote IO Edge Gateway\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003cdiv class=\"attribute-list\"\u003e\r\n\u003cdiv class=\"attribute-item\"\u003e\r\n\u003cdiv class=\"left\" data-spm-anchor-id=\"a2700.wholesale.0.i41.58d89115Ba50Fd\"\u003e\r\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\" valign=\"top\" width=\"590\" data-spm-anchor-id=\"a2700.wholesale.0.i88.58d89115Ba50Fd\"\u003e\r\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-spm-anchor-id=\"a2700.wholesale.0.i87.58d89115Ba50Fd\"\u003ePower supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp data-spm-anchor-id=\"a2700.wholesale.0.i86.58d89115Ba50Fd\"\u003eInput Voltage\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e9 – 36 VDC, reverse polarity protection, surge protection\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003ePower Consumption\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eIdle: \u0026lt; 2.4W, Max: \u0026lt; 4.8W\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eSerial port\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eNo.\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e2 RS485 serial port, the first one can also be RS232\u003c\/p\u003e\r\n\u003cp\u003eRS232 Terminal block connector: TX, RX\u003c\/p\u003e\r\n\u003cp\u003eRS485 Terminal block connector: A, B\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eBaud rates\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e600~230400 bps\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eData bits\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"center\" width=\"421\"\u003e\r\n\u003cp\u003e7,8 \u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eStop bits\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"center\" width=\"421\"\u003e\r\n\u003cp\u003e1,2\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eParity\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"center\" width=\"421\"\u003e\r\n\u003cp\u003eNone,Even,Odd,Mark,Space\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eFlow\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"center\" width=\"421\"\u003e\r\n\u003cp\u003eNone,XON\/XOFF\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\" valign=\"top\" width=\"590\"\u003e\r\n\u003cp\u003e\u003cstrong\u003ePhysical interface\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eDI\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e2 x Digital non-isolated input (0 - 2 V detected as logic low, 9 - 36 V detected as logic high)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eDO\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e2 x Relays\u003c\/p\u003e\r\n\u003cp\u003eDC contacts rating @R(at resistive load)10A \/ 28V DC\u003c\/p\u003e\r\n\u003cp\u003eAC contacts rating @R(at resistive load)10A \/ 277V AC,NO\u003c\/p\u003e\r\n\u003cp\u003eAC contacts rating @R(at resistive load)5A \/ 250V AC, NC\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eAI\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e2 x Analog input 4-20mA\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eExtendable I\/O modules\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eUSR-IO4040: 4 x Digital input , 4 x Digital output\u003c\/p\u003e\r\n\u003cp\u003eUSR-IO0440: 4 x Analog input(4-20mA), 4 x Digital output\u003c\/p\u003e\r\n\u003cp\u003eUSR-IO0080: 8 x Digital output\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\" valign=\"top\" width=\"590\"\u003e\r\n\u003cp\u003e\u003cstrong\u003ePhysical spec\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eDimensions (W x H x D)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e79.6 x 58 x 110 (mm)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eMounting options\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eDIN rail, wall mounting\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\" valign=\"top\" width=\"590\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eHardware protection\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eESD\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"center\" width=\"421\"\u003e\r\n\u003cp\u003eIEC61000-4-2,Level 3,class B,contact 6KV,air 8KV\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eSurge\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"center\" width=\"421\"\u003e\r\n\u003cp\u003eIEC61000-4-5,Level 3,class B\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eEFT\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"center\" width=\"421\"\u003e\r\n\u003cp\u003eIEC61000-4-4,Level 3,class B\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\" valign=\"top\" width=\"590\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eStatus LEDS\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003ePower\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eON: Gateway is powered up\u003c\/p\u003e\r\n\u003cp\u003eOFF: Gateway is not power up\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eWork\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eWhen the device is working properly, it blinks for 1s frequency\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eNET\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eBlinking when the wan connects to internet\u003c\/p\u003e\r\n\u003cp\u003eOFF when there is no work\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eDATA\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eBlinking when serial port is transmitting data\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eDO\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eLight on, the channel output is activated\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eDI\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eLight on, the channel is activated by input signal\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\" valign=\"top\" width=\"590\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eNetwork\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eCellular\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eLTE FDD: B1\/3\/5\/7\/8\/20\/28\u003c\/p\u003e\r\n\u003cp\u003eLTE TDD: B38\/40\/41\u003c\/p\u003e\r\n\u003cp\u003eWCDMA: B1\/5\/8\u003c\/p\u003e\r\n\u003cp\u003eGSM\/GPRS\/EDGE: 850\/900\/1800\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eETHERNET\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e1 x WAN port  10\/100 Mbps, compliance IEEE 802.3, IEEE 802.3u standards, supports auto MDI\/MDIX\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\" valign=\"top\" width=\"590\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eNetwork protocols\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eICMP,IPv4,IPv4,ARP,ICMP,TCP,UDP,DHCP,DNS,HTTPS,MQTT,SNMP,Telnet,NTP,SSL v3\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eIP\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eDHCP\/StaticIP\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eWebsocket\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eSupported\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eMQTT\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eSupported, standard MQTT protocol, 16 subscription topics and 16 publish topics\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eLinkage control\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eSupported. Data collection points, DI, and AI can be used as trigger and executed by DO\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eIOT PLATFORMS\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eAlibaba cloud, AWS IOT ,PUSR cloud, Microsoft Azure, ThingsBoard\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eUser Configuring\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eWindows Utility, web console(HTTP)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\" valign=\"top\" width=\"590\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eOperating temperature\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e-40 °C to 75 °C\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eOperating humidity\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e10% to 90% non-condensing\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eIngress Protection Rating\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eIP30\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\" valign=\"top\" width=\"590\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eMODBUS RTU master\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eSupported functions\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e01, 02, 03, 04\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eSupported data formats\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e8 bit: INT, UINT; 16 bit: INT, UINT (MSB first); 32 bit: float, INT, UINT (ABCD (big-endian), DCBA (little-endian), CDAB);64bit:float\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003eSupported data points\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003e128\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"2\" valign=\"top\" width=\"590\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eAPPROVALS\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd valign=\"top\" width=\"169\"\u003e\r\n\u003cp\u003e\u003cstrong\u003eRegulatory\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd valign=\"top\" width=\"421\"\u003e\r\n\u003cp\u003eCCC,CE\/RED*,RoHS*\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eIO Edge Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eExpandable | Remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"UsrIoT","offers":[{"title":"Default Title","offer_id":45625417990188,"sku":"USR M100-EAU REMOT IO EDG GATEWY","price":3100.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/usr-m100-eau-remot-io-edg-gatewy-872193.jpg?v=1781021709","url":"https:\/\/xytron.ae\/ar\/products\/usr-m100-eau-remot-io-edg-gatewy","provider":"Xytron","version":"1.0","type":"link"}