{"product_id":"fnirsi-lc1020e-prec-lcr-meter","title":"FNIRSI LC1020E PREC LCR METER","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eFNIRSI LC1020E Handheld LCR\/ESR Tester – High‑Precision Bridge Meter for Inductance, Capacitance, Resistance and ESR with Clear Digital Display, Wide Test Range and Portable Design.\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eLC1020E Handheld LCR\/ESR Tester\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003eFNIRSI® LC1020E High-Precision Handheld LCR Meter is a portable and intelligent tool for testing electronic components, ideal for engineers, technicians, and hobbyists. It supports L\/Q, C\/D, and R\/D measurements with series\/parallel models, and features a 2.8-inch TFT color display.\r\nWith preset thresholds and audio-visual alerts, it enables fast pass\/fail judgments, improving batch testing and quality control. Supporting up to 100 kHz test frequency, it handles high-frequency analysis of inductors, capacitors, and resistors. Its compact, battery-powered design allows precise, cable-free measurements anytime, anywhere.\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\u003cul\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eHigh-Precision Measurement with 4.5-Digit Resolution\u003c\/strong\u003e\u003cbr\u003e Achieves up to \u003cstrong\u003e±0.05% basic accuracy\u003c\/strong\u003e, offering \u003cstrong\u003e10× improved precision\u003c\/strong\u003efor professional-grade measurements.\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eWide Parameter Support\u003c\/strong\u003e\u003cbr\u003e Measures \u003cstrong\u003eL\/C\/R\/Z values\u003c\/strong\u003ewith automatic mode switching, and displays \u003cstrong\u003eX\/D\/Q\/θ\/ESR\u003c\/strong\u003e as secondary parameters for comprehensive component analysis.\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eSmart Auto Component Identification\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eAutomatically recognizes R\/L\/C components\u003c\/strong\u003eand switches modes instantly — ensuring \u003cstrong\u003efast and efficient testing\u003c\/strong\u003e with minimal manual input.\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eMulti-Frequency \u0026amp; Test Voltage Selection\u003c\/strong\u003e\u003cbr\u003e Supports \u003cstrong\u003e5 test frequencies\u003c\/strong\u003e: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz\u003cbr\u003e Offers \u003cstrong\u003e3 RMS test levels\u003c\/strong\u003e: 0.1V, 0.3V, 0.6V — providing \u003cstrong\u003eprecise control across different testing scenarios\u003c\/strong\u003e.\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eSorting \u0026amp; Comparison Function\u003c\/strong\u003e\u003cbr\u003e Set \u003cstrong\u003enominal values and tolerances (0.1%–99.9%)\u003c\/strong\u003efor automatic \u003cstrong\u003epass\/fail judgment\u003c\/strong\u003e, with \u003cstrong\u003eaudio-visual prompts\u003c\/strong\u003e for fast \u003cstrong\u003ebatch testing and quality control\u003c\/strong\u003e.\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eInternal Bias Voltage\u003c\/strong\u003e\u003cbr\u003e Built-in bias voltage \u003cstrong\u003estabilizes readings\u003c\/strong\u003eand enhances measurement accuracy for \u003cstrong\u003esensitive components\u003c\/strong\u003e.\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eDual Test Ports: 3-Terminal \u0026amp; 5-Terminal (4-Wire Kelvin)\u003c\/strong\u003e\u003cbr\u003e Ensures both \u003cstrong\u003eease of use and maximum accuracy\u003c\/strong\u003eby minimizing lead resistance error.\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eDual-Parameter Display on 2.8\" TFT Screen\u003c\/strong\u003e\u003cbr\u003e Clearly shows both main and secondary parameters in real time — \u003cstrong\u003eeasy to read anytime, anywhere\u003c\/strong\u003e.\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eOpen \u0026amp; Short Calibration\u003c\/strong\u003e\u003cbr\u003e Calibrate test fixtures and eliminate system errors for \u003cstrong\u003eaccurate and repeatable results\u003c\/strong\u003e.\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eData Hold \u0026amp; Logging Mode\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eShort press\u003c\/strong\u003eto hold reading, \u003cstrong\u003elong press\u003c\/strong\u003e to enter logging mode — with \u003cstrong\u003ecategorized statistics\u003c\/strong\u003e on pass\/fail results for improved test efficiency.\u003c\/li\u003e\r\n\u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Rechargeable Design\u003c\/strong\u003e\u003cbr\u003e Lightweight, portable body powered by a \u003cstrong\u003e7V 3000mAh lithium battery\u003c\/strong\u003e, perfect for \u003cstrong\u003elab, production line, and field use\u003c\/strong\u003e.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eModel\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eLC1020E\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eTest Frequency\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e100Hz, 120Hz, 1KHz, 10KHz, 100KHz\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eBasic Accuracy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e0.3%\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eDisplay\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e2.8-inch TFT LCD\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eDisplay Digits\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eMain: 4.5 digits\u003cbr\u003e Secondary: 4.5 digits\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eMeasurement Parameters\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eMain: AUTO \/ R \/ C \/ L \/ Z\u003cbr\u003e Secondary: X \/ D \/ Q \/ θ \/ ESR\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eMeasurement Range\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eL: 0–100 H\u003cbr\u003e C: 0–100 mF\u003cbr\u003e R: 0–10 MΩ\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eInternal Bias\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e0.0V, 0.5V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eTest Level\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e0.1V, 0.3V, 0.6V\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eCalibration Functions\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eOpen circuit calibration, Short circuit calibration\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eComparison Function\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eCalculates relative error vs nominal value (%), provides filtering, tolerance adjustable 0.1%–99.9%\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eFunction Record\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eRecords number of successful and failed measurements\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eTest Terminal Configuration\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eThree-terminal, Five-terminal\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eOutput Impedance\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e100Ω\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eCommunication Interface\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eUSB-Type C (Virtual serial port)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eOther Features\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eLanguage settings, screen brightness, sound settings, auto power-off, calibration settings, system information\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePrecautions:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eAmbient temperature: 20 °C ± 2 °C\u003c\/li\u003e\r\n\u003cli\u003eHumidity: ≤ 80 % RH\u003c\/li\u003e\r\n\u003cli\u003ePreheat instrument ≥ 30 minutes\u003c\/li\u003e\r\n\u003cli\u003eUse front panel test slots\u003c\/li\u003e\r\n\u003cli\u003ePerform open\/short circuit calibration before testing\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003eCapacitance (C)\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ctable\u003e\r\n\u003cthead\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eLC1020E LCR Meter\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e1\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eData Cable\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e1\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eShorting Plate\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e1\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eKelvin Test Clip\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e1\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eTest Leads (Black \u0026amp; Red)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e2\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003eUser Manual\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd\u003e\r\n\u003cp\u003e1\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eTester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eLC1020E | Handheld | LCR\/ESR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fnirsi","offers":[{"title":"Default Title","offer_id":45624981717036,"sku":"FNIRSI LC1020E PREC LCR METER","price":1391.3,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/fnirsi-lc1020e-prec-lcr-meter-8820555_b4a8b20e-1f6d-431b-828e-4187a1f00deb.jpg?v=1781109560","url":"https:\/\/xytron.ae\/ar\/products\/fnirsi-lc1020e-prec-lcr-meter","provider":"Xytron","version":"1.0","type":"link"}