{"product_id":"fluke-t6-1000-pro","title":"FLUKE T6-1000 PRO","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eElectrical Tester 1000V AC\/DC, Resolution:1V, Freq:45hz~66hz Through Open Fork, Resistance:1ω~100kω, AC Current:0.1~200A AC, True RMS, CatIII 1000V\u003c\/span\u003e\u003c\/div\u003e\n\u003ch1\u003e1000V AC\/DC Electrical Tester\u003c\/h1\u003e\n\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eSave time by seeing voltage and current measurements at the same time\u003c\/li\u003e\n\u003cli\u003eVisual Continuity™ – the screen automatically turns green for continuity, perfect when it’s too loud to hear the beeper\u003c\/li\u003e\n\u003cli\u003eFieldSense™ technology for ac voltage, current and frequency, all without making electrical contact to live voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFunction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFieldSense ac voltage\u003c\/td\u003e\n\u003ctd\u003eRequires test leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3 % + 3 counts) 45 Hz - 66 Hz\u003csup\u003e[1] [2]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFieldSense ac current\u003c\/td\u003e\n\u003ctd\u003eRequires test leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e200.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3 % + 3 counts) 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFieldSense frequency (Hz)\u003c\/td\u003e\n\u003ctd\u003eRequires test leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e45 Hz – 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eVolts ac\u003c\/td\u003e\n\u003ctd\u003eRequires test leads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.5 % + 2 counts) 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eVolts dc\u003c\/td\u003e\n\u003ctd\u003eRequires test leads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eRequires test leads (all ranges)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e100.0 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (all ranges)\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAccuracy\u003csup\u003e[1]\u003c\/sup\u003e: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, RMS responding.\u003c\/p\u003e\n\u003cp\u003eAccuracy\u003csup\u003e[2]\u003c\/sup\u003e: FieldSense specified from 16V to 1000V.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1-year calibration cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e61 mm x 259 mm x 43 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg (0.78 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFork opening\u003c\/td\u003e\n\u003ctd\u003e17.8 mm (0.7”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003cbr\u003eOperating:\u003cbr\u003eStorage:\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e-10 °C to +50 °C (14 °F to 122 °F)\u003cbr\u003e-30 °C to +60 °C (-22 °F to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003cbr\u003eOperating:\u003cbr\u003eStorage:\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e2,000 m (6,562 feet)\u003cbr\u003e10,000 m (32,808 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)\u003cbr\u003e0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)\u003cbr\u003e0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eBattery\u003c\/strong\u003e\u003cbr\u003eType:\u003cbr\u003eLife:\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003e2x AA (IEC LR6)\u003cbr\u003e360 hour continuous, typical is 200 hour using the FieldSense function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd\u003e0.1 x (specified accuracy) \/ °C for \u0026lt;18°C or \u0026gt;28 °C (\u0026lt; 64.4 °F or \u0026gt; 82.4 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSafety\u003c\/strong\u003e\u003cbr\u003eGeneral:\u003cbr\u003eMeasurement\u003cbr\u003eT6-1000 PRO:\u003c\/td\u003e\n\u003ctd\u003e\n\u003cbr\u003eIEC 61010-1: Pollution Degree 2\u003cbr\u003e\u003cbr\u003eIEC 61010-2-032: CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003col\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D1725209158.pdf\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable border=\"1\" cellpadding=\"7\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eTester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eElectrical | Tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45625031229484,"sku":"FLUKE T6-1000 PRO","price":9680.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/fluke-t6-1000-pro-2889363_5c952d10-c15a-41b1-93d8-3ec13c260026.jpg?v=1781109881","url":"https:\/\/xytron.ae\/ar\/products\/fluke-t6-1000-pro","provider":"Xytron","version":"1.0","type":"link"}