{"product_id":"fluke-t5-600","title":"FLUKE T5-600","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eElectrical Tester 600VAC\/DC,100A AC\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eElectrical Tester 600VAC\/DC,100A AC\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe T5-600 Electrical Tester is a versatile troubleshooting tool you can carry to every job site. Use it to check voltage, continuity, and current, all with one compact, rugged tool. Just select volts, ohms, or current and the tester does the rest. For higher voltage applications check out the Fluke T5-1000.\u003c\/p\u003e\r\n\u003cp\u003eMeasure current up to 100 A without breaking the circuit with OpenJawâ„¢ design\u003c\/p\u003e\r\n\u003cp\u003eThe trendsetting OpenJawâ„¢ design allows for fast and easy current measurement, safely and without metallic contact to a live conductor. The integrated protection circuit allows it to stay connected to a voltage source longer than a solenoid tester would be able to. The T5-600 is also designed to:\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eWithstand a 10 ft. (3 m) drop\u003c\/li\u003e\r\n\u003cli\u003eConserve battery life with auto-off mode\u003c\/li\u003e\r\n\u003cli\u003eFit in one hand with handy probe storage in the back of the holster\u003c\/li\u003e\r\n\u003cli\u003eAccept Fluke accessory test clips with the test leads\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eMeter automatically selects AC or DC voltage for tests up to 600 V\u003c\/p\u003e\r\n\u003cp\u003eVoltage tests are faster and easier than ever before. Just turn the knob to voltage (V) and place your leads on the test points. The T5-600 auto-selects either AC or DC voltage, depending on what is detected. This meter is suitable for both residential or commercial applications and is designed to keep you safe with a CAT III 600 V rating.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\u003cul\u003e\r\n\u003cli\u003eMeasure current up to 100 A without breaking the circuit\u003c\/li\u003e\r\n\u003cli\u003eMeter automatically selects AC or DC voltage, up to 600 V\u003c\/li\u003e\r\n\u003cli\u003eResistance measurements up to 1000 Î© plus continuity test\u003c\/li\u003e\r\n\u003cli\u003eWork in tight spaces with detachable SlimReachâ„¢ probe tips\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eJaw opening\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e12.9 mm (0.5 in)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMax wire size\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1\/0 THHN Cable\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCurrent range AC rms\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0 to 100.0 A\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy AC current (50\/60 Hz)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e3% Â± 3 counts\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAC response\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eAveraging\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVoltage range AC\/DC\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0 to 600 V\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eVoltage accuracy\u003c\/td\u003e\r\n\u003ctd width=\"10%\"\u003e\u003cstrong\u003eAC\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e1.5% Â± 2 counts\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDC\u003c\/td\u003e\r\n\u003ctd\u003e1% Â± 1 count\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResistance range\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0 to 1000 Î©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eContinuity beeper threshold\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eOn at \u0026lt; 25 Î©, off at \u0026gt; 400 Î©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVolts indicator LED threshold\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eGuaranteed on by 30 V AC\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-10Â°C to 50Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-30Â°C to 60Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eHumidity (without condensation)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0% to 95% (5Â°C to 30Â°C);\u003cbr\u003e0% to 75% (30Â°C to 40Â°C);\u003cbr\u003e0% to 45% (40Â°C to 50Â°C)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDust\/water resistance\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2000 meters max\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1 x (specified accuracy)\/Â°C (\u0026lt; 18Â°C or \u0026gt; 28Â°C)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMeasurement Category\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eIEC 61010-2-032, IEC61010-2-033: CAT III 600 V, 100 A ac\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eCSA, TUV\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e600 V between any terminal and earth ground\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSize\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e30.5 x 51 x 203 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e300 g\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWarranty\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eTwo-years\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBattery life\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e200 hour zinc chloride, 400 hour alkaline\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBattery type\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2 x AA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eLow battery indicator\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCurrent sensor opening\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e12.9 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D3312333255.pdf\"\u003eDatasheet - FLUKE T5-600\u003c\/a\u003e\u003c\/li\u003e\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eTester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eElectrical | 600VAC\/DC,100A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45627366670380,"sku":"FLUKE T5-600","price":5125.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/fluke-t5-600-9278735.jpg?v=1781042094","url":"https:\/\/xytron.ae\/ar\/products\/fluke-t5-600","provider":"Xytron","version":"1.0","type":"link"}