{"product_id":"fluke-59max","title":"FLUKE 59MAX+","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eIP40 Digital Infrared Thermometer with 0-500°C Temperature Range and 10:1 Distance to Spot ratio\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eDigital Infrared Thermometer\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Fluke 59 MAX+ Infrared Thermometer delivers the precision you need to do your job accurately and within your budget. It features a 10:1 distance to spot ratio and precise single laser targeting for accurate and repeatable measurements. Use the Fluke 59 MAX+ to perform non-contact temperature measurements on transformers, motors, pumps, panels, breakers, compressors, duct, and vents. It is extremely easy to use and compact enough to fit in your hand and your tool bag. Designed to withstand a one meter drop, you can count on this lightweight, compact infrared thermometer to work when you need it.\u003c\/p\u003e\r\n\u003cp\u003eFor a 12:1 distance to spot ratio, dual laser targeting check out the Fluke 62MAX+ thermometer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\u003cul\u003e\r\n\u003cli\u003eProvides selectable MAX, MIN, DIF and AVG functions to quickly identify problems\u003c\/li\u003e\r\n\u003cli\u003eOne meter drop tested\u003c\/li\u003e\r\n\u003cli\u003eIncludes Hi and Lo alarms for rapid display of measurements outside the limits\u003c\/li\u003e\r\n\u003cli\u003eRuns on one (1) AA battery\u003c\/li\u003e\r\n\u003cli\u003eComes with a one year warranty\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-30°C to 500°C (-22°F to 932°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"6\"\u003eAccuracy (Calibration geometry with ambient temperature 23°C ±2°C)\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003e≥ 0°C\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e±1.5°C or ±1.5% of reading, whichever is greater\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e≥ -10°C to \u0026lt; 0°C:\u003c\/td\u003e\r\n\u003ctd\u003e±2.0°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u0026lt; -10°C\u003c\/td\u003e\r\n\u003ctd\u003e±3.0°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e≥ 32°F\u003c\/td\u003e\r\n\u003ctd\u003e±3.0°F or ±1.5% of reading, whichever is greater\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e≥ 14°F to \u0026lt; 32°F\u003c\/td\u003e\r\n\u003ctd\u003e±4.0°F\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u0026lt; 14°F:\u003c\/td\u003e\r\n\u003ctd\u003e±6.0°F\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResponse Time (95%)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e\u0026lt; 500 ms (95% of reading)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSpectral Response\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e8 mm to 14 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eEmissivity\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.10 to 1.00\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDistance to Spot Ratio\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e10:1 (calculated at 90% energy)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0.1°C (0.2°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eRepeatability (% of reading)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e±0.8% of reading or ±1.0°C\u003cbr\u003e(±2.0°F), whichever is greater\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePower\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1 AA IEC LR06 Battery\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBattery Life\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e12 hours with laser and backlight on\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e220 g (7.76 oz)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSize\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e156 x 80 x 50 mm (6.14 x 3.15 x 2 in)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-20°C to +60°C (-4°F to 140°F), (without battery)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e10% to 90% RH non-condensing @ 30°C (86°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2000 meters above mean sea level\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDrop Test\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd\u003eIngress Protection Rating\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eIP40 per IEC 60529\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVibration and Shock\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCompliance\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eEN\/IEC 61010-1\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eLaser Safety\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eFDA and EN 60825-1 Class II\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eElectromagnetic Compatibility\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e61326-1 EN 61326-2\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D3858996130.pdf\"\u003eDatasheet- FLUKE 59MAX\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D3094903647.pdf\"\u003eManual - FLUKE 59 MAX\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eThermometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDigital | Infrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45639595098156,"sku":"FLUKE 59MAX+","price":2518.75,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/fluke-59max-8804043.jpg?v=1781172079","url":"https:\/\/xytron.ae\/ar\/products\/fluke-59max","provider":"Xytron","version":"1.0","type":"link"}