{"product_id":"fluke-1550c","title":"FLUKE 1550C","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eInsulation Resistance Tester (5KV) 1TÎ© CAT III 1000V, CAT IV 600V\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eInsulation Resistance Tester\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003eThe Fluke 1550C performs digital insulation testing up to 5 kV, and makes data collection easy through the Fluke Connectâ„¢ wireless app. Remote operation lets you spend as little time as possible in potentially hazardous zones. Real-time trending shows a live graph on your phone, rather than a hard-to-read set of changing values. And you can create reports quickly, using pre-designed templates that you can customize with company logos. Itâ€™s the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. And it comes with a three-year warranty and CAT IV 600 V safety rating.\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\u003cul\u003e\r\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\r\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\r\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\r\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\r\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\r\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\r\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\r\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\r\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\r\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\r\n\u003cli\u003eResistance measurements up to 2 TÎ©\u003c\/li\u003e\r\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\r\n\u003cli\u003e3-year warranty\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable\u003e\r\n\u003ctbody\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eInsulation Resistance Measurement\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd colspan=\"3\"\u003eTest voltage (DC)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003e250 V\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 250 kÎ©,\u003cbr\u003e250 kÎ© to 5 GÎ©\u003cbr\u003e5 GÎ© to 50 GÎ©\u003cbr\u003e\u0026gt; 50 GÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy (Â± reading)\u003c\/td\u003e\r\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003e500 V\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 500 kÎ©\u003cbr\u003e500 kÎ© to 10 GÎ©\u003cbr\u003e10 GÎ© to 100 GÎ©\u003cbr\u003e\u0026gt; 100 GÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy (Â± reading)\u003c\/td\u003e\r\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003e1000 V\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 1 MÎ©\u003cbr\u003e1 MÎ© to 20 GÎ©\u003cbr\u003e20 GÎ© to 200 GÎ©\u003cbr\u003e\u0026gt; 200 GÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy (Â± reading)\u003c\/td\u003e\r\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003e2500 V\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 2.5 MÎ©\u003cbr\u003e2.5 MÎ© to 50 GÎ©\u003cbr\u003e50 GÎ© to 500 GÎ©\u003cbr\u003e\u0026gt; 500 GÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy (Â± reading)\u003c\/td\u003e\r\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003e5000 V\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u0026lt; 5 MÎ©\u003cbr\u003e5 MÎ© to 100 GÎ©\u003cbr\u003e100 GÎ© to 1 TÎ©\u003cbr\u003e\u0026gt; 1 TÎ©\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy (Â± reading)\u003c\/td\u003e\r\n\u003ctd\u003eUnspecified\u003cbr\u003e5%\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eBar graph range\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e0 to 1 TÎ© (1550C) - 0 to 2 TÎ© (1555)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eInsulation test voltage accuracy\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-0%, +10% at 1 mA load current\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eInduced AC mains current rejection\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2 mA maximum\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCharging rate for capacitive load\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e5 seconds per Î¼F\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDischarge rate for capacitive load\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1.5 s\/Î¼F\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eLeakage current measurement\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e1 nA to 2 mA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ± (5% + 2 nA)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eCapacitance measurement\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e0.01 Î¼F to 15.00 Î¼F\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAccuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ± (15% rdg + 0.03 Î¼F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"3\"\u003eTimer\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e0 to 99 minutes\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution setting\u003c\/td\u003e\r\n\u003ctd\u003e1 minute\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eResolution indication\u003c\/td\u003e\r\n\u003ctd\u003e1 second\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd rowspan=\"2\"\u003eLive circuit warning\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eWarning range\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e30 V to 660 V AC\/DC, 50\/60 Hz\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eVoltage accuracy\u003c\/td\u003e\r\n\u003ctd\u003eÂ± (15% + 2 V)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSoftware specifications\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eFlukeView Formsâ„¢ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"head\"\u003e\r\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDisplay\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e75 x 105 mm\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ePower\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e12 V lead-acid rechargeable battery, Yuasa NP2.8-12\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eCharger Input (AC)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e85 V to 250 V AC 50\/60 Hz 20 VA\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThis Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDimensions\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eWeight\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e3.7 kg (8.2 lb)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTemperature (operating)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-20Â°C to 50Â°C (-4Â°F to 122Â°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eTemperature (storage)\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e-20Â°C to 65Â°C (-4Â°F to 149Â°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eHumidity\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e80% to 31Â°C decreasing linearly to 50% at 50Â°C\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eAltitude\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eEnclosure sealing\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eInput overload protection\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003e1000 V AC\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eEN 61326\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\r\n\u003ctd colspan=\"2\"\u003eIEC 61010-1: Overvoltage category II, Pollution Degree 2.\u003cbr\u003eIEC 61010-2-030: Measurement 600V CAT IV \/ 1000V CAT III\u003cbr\u003eIEC 61557-1, IEC 61557-2\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D2556561423.pdf\"\u003eDatasheet - FLUKE 1550C\u003c\/a\u003e\u003c\/li\u003e\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eTester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eInsulation | Resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":45627369324588,"sku":"FLUKE 1550C","price":114990.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/fluke-1550c-9152406.jpg?v=1781042125","url":"https:\/\/xytron.ae\/ar\/products\/fluke-1550c","provider":"Xytron","version":"1.0","type":"link"}