{"product_id":"cp8844u-kit","title":"CP8844U KIT","description":"\u003cdiv class=\"communicaintro\"\u003eGSM Controller Kit with 8 Digital Inputs, 8 Digital Outputs, 4 Analog Output and SD Card Logger. Kit Includes GSM Antenna, Battery, Software and Communicator Module\u003c\/div\u003e\n\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Cellcop GSM communicator system is based on SMS and GPRS technology. It uses standard cellphone technology for communication and has been designed to provide you with the greatest possible flexibility and convenience. Read this manual carefully and have your installer instruct you on your system’s operation and on which features have been implemented in your system. All users of this system should be equally instructed in its use.\u003c\/p\u003e\n\u003cp\u003eThe cellcop communicator can be used in various applications to monitor and control system alarms and parameters remotely using your cellphone. The unit can be configured to your requirements by using the configuration tool. The configuration tool allows the user to setup various options by setting the parameters and sending the setup to the cellcop. Using the configuration tool you can setup the Cellcop directly using a USB cable connected to the to the cellcop or remotely by connecting a GSM modem to the PC running the configuration tool and connect to the cellcop using a data call. The configuration can be backed up to a file using the configuration tool, for easy reuse in future or quickly setting up multiple boards with the same configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003e8 Inputs to communicate separate alarm conditions\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEach input can be triggered to send an SMS to up to 16 Cellphone numbers\u003c\/li\u003e\n\u003cli\u003eThe time delay before the input is triggered can be set for each input\u003c\/li\u003e\n\u003cli\u003eSeparate messages can be configured for On and Off states of the input signal\u003c\/li\u003e\n\u003cli\u003eMessages to be send can be programmed by the user\u003c\/li\u003e\n\u003cli\u003eOn or Off states can both be reported to predefined cellphone numbers.\u003c\/li\u003e\n\u003cli\u003eReporting can be disabled for an input\u003c\/li\u003e\n\u003cli\u003eThe states of the inputs can be requested from the unit by SMS\u003c\/li\u003e\n\u003cli\u003eMonitoring of the inputs can be controlled using different modes\u003c\/li\u003e\n\u003cli\u003eInputs can act as counters\u003c\/li\u003e\n\u003cli\u003eInputs can act as Run Hour meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e4 Analog Inputs\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEach analog input can perform a analog measurement and report 2 High alarmsand 2 low alarms per input.\u003c\/li\u003e\n\u003cli\u003eTime delay can be configured for each alarm\u003c\/li\u003e\n\u003cli\u003eAnalog alarm levels can control relay outputs to enable analog control functionality.\u003c\/li\u003e\n\u003cli\u003eAnalog changes can be logged to a server via GPRS communications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e8 Outputs to control any electrical device\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutputs can be controlled by cellphone using SMS on, off or pulse\u003c\/li\u003e\n\u003cli\u003eOutput controls can be scheduled\u003c\/li\u003e\n\u003cli\u003eThe duration of the pulse can be programmed for each output\u003c\/li\u003e\n\u003cli\u003eOutputs can be set to follow the state of an input\u003c\/li\u003e\n\u003cli\u003eOutput can be set to switch on when the unit is dialed\u003c\/li\u003e\n\u003cli\u003eStatus of an output can be requested from the unit by SMS\u003c\/li\u003e\n\u003cli\u003eAnalog Limits can control the switching of outputs\u003c\/li\u003e\n\u003cli\u003eOwn text can be used to control outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMonitor AC power using the charger input\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC power can be monitored by using the charger input.\u003c\/li\u003e\n\u003cli\u003eSMS can be send to up to 16 numbers when an power failure occur and when the power return\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMonitor the battery status\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe battery status can be monitored by the system.\u003c\/li\u003e\n\u003cli\u003eSMS can be send to up to 16 numbers when the battery go faulty.\u003c\/li\u003e\n\u003cli\u003eThe battery is monitored by disconnecting it from the main supply and to measure the battery voltage while connected to a load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRemote Program Commands via SMS \/ GPRS * The setting of configuration parameters remotely by SMS or GPRS.\u003c\/p\u003e\n\u003cp\u003eRemote Control Program Commands via SMS \/ GPRS\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe execution of Control Commands remotely by SMS or GPRS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eScheduled Commands\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe execution of commands can be scheduled\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSD Card Logger\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe system will log events configured to be logged\u003c\/li\u003e\n\u003cli\u003eLogged events will be time stamped from the Cell phones Date\/Time\u003c\/li\u003e\n\u003cli\u003eEvents can be downloaded into a comma delimited file for analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMonitor Mode\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMonitor mode is used to activate monitor functions\u003c\/li\u003e\n\u003cli\u003eMonitor Mode can be set by SMS or Monitor mode Inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLCD Add on\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay Status information on LCD display\u003c\/li\u003e\n\u003cli\u003eMultiple pages on LCD Display\u003c\/li\u003e\n\u003cli\u003ePages configurable to user requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCustom Status Message\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCustom status reply messages can be configured\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfiguration tool to configure unit to user requirements\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll parameters can be set from configuration tool.\u003c\/li\u003e\n\u003cli\u003eRemote programming possible from the configuration tool\u003c\/li\u003e\n\u003cli\u003eSave and Load from files for backup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecification\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003eTypical hardware requirements\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCP8844u-M Communicator module\u003c\/li\u003e\n\u003cli\u003eSIM card (Must be a RICA card)\u003c\/li\u003e\n\u003cli\u003ePower harness connector\u003c\/li\u003e\n\u003cli\u003eInputs harness connector (Digital 1-8, Analog 1-4)\u003c\/li\u003e\n\u003cli\u003eOutput harness connector\u003c\/li\u003e\n\u003cli\u003eMode inputs harness connector\u003c\/li\u003e\n\u003cli\u003eGSM Antenna\u003c\/li\u003e\n\u003cli\u003ePower supply \/ Charger\u003c\/li\u003e\n\u003cli\u003eMicro SD card\u003c\/li\u003e\n\u003cli\u003eRelay board if unit will be used to switch external equipment\u003c\/li\u003e\n\u003cli\u003ePC running configuration software and USB cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKit Includes\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCP8844U-M Logger\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eGSM Antenna\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003eProduct Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D2869719517.zip\" target=\"_blank\" title=\"PDF Datasheet\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #3d85c6;\"\u003eSoftware Download\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D0861221147.pdf\" target=\"_blank\" title=\"PDF Datasheet\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #3d85c6;\"\u003eDatasheet Download\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n","brand":"Communica","offers":[{"title":"Default Title","offer_id":44755381223468,"sku":"CP8844U KIT","price":5295.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/cp8844u-kit-262206.jpg?v=1757324721","url":"https:\/\/xytron.ae\/ar\/products\/cp8844u-kit","provider":"Xytron","version":"1.0","type":"link"}