{"product_id":"bmt-stc-3028-temp-humid-control","title":"BMT STC-3028 TEMP\/HUMID CONTROL","description":"\u003cdiv class=\"communicaintro\"\u003e\u003cspan\u003eSTC-3028 Dual Display Temperature and Humidity Controller. AC 110-220V. Dual Relay Rated AT 10A\u003c\/span\u003e\u003c\/div\u003e\u003ch1\u003eDual Display Temperature and Humidity Controller\u003c\/h1\u003e\u003cdiv class=\"communicadesc\"\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cdiv\u003e\u003cul\u003e\r\n\u003cli\u003eMini and lightweight design\u003c\/li\u003e\r\n\u003cli\u003eLarge and clear LCD display\u003c\/li\u003e\r\n\u003cli\u003eWide temperature range (-50-99°C temperature)\u003c\/li\u003e\r\n\u003cli\u003eDual heating and cooling\u003c\/li\u003e\r\n\u003cli\u003eAutomatic over temperature alarm\u003c\/li\u003e\r\n\u003cli\u003eControl the temperature by setting the temperature setpoint and different values\u003c\/li\u003e\r\n\u003cli\u003eTemperature calibration\u003c\/li\u003e\r\n\u003cli\u003eCooling control output delay protection\u003c\/li\u003e\r\n\u003cli\u003eIncluding installation wiring diagram\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cul\u003e\r\n\u003cli\u003eColor: Black\u003c\/li\u003e\r\n\u003cli\u003eApplication: Aquarium, Crystal Ball, Animal Feeding, Paludarium, Chicken Incubator\u003c\/li\u003e\r\n\u003cli\u003eControl temperature range: -50 - 90 °C temperature (adjustable)\u003c\/li\u003e\r\n\u003cli\u003eControl temperature difference: 0.3 - 10 °C temperature (adjustable)\u003c\/li\u003e\r\n\u003cli\u003eResolution: 0.1 °C temperature\u003c\/li\u003e\r\n\u003cli\u003eAccuracy: ±1 °C temperature (-50 - 70 °C insulation)\u003c\/li\u003e\r\n\u003cli\u003eSensor: NTC sensor\u003c\/li\u003e\r\n\u003cli\u003eSensor failure delay: 2 minutes\u003c\/li\u003e\r\n\u003cli\u003eRelay contact capacity (heating): 10A (maximum) 250 V\u003c\/li\u003e\r\n\u003cli\u003eRelay contact capacity (cooling): 10 A (max) 250 V\u003c\/li\u003e\r\n\u003cli\u003eCompressor delay protection time: 1~10 minutes (adjustable)\u003c\/li\u003e\r\n\u003cli\u003eWorking temperature: 0 - 60 °C temperature\u003c\/li\u003e\r\n\u003cli\u003eStorage temperature: -30 - 75 °C temperature\u003c\/li\u003e\r\n\u003cli\u003eWorking relative humidity: 20~85% (no condensation)\u003c\/li\u003e\r\n\u003cli\u003eAlarm output: buzzer\u003c\/li\u003e\r\n\u003cli\u003ePower supply: AC110~220V 50\/60 Hz\u003c\/li\u003e\r\n\u003cli\u003ePower consumption: \u0026lt;3 W\u003c\/li\u003e\r\n\u003cli\u003eCable length: 1 meter\u003c\/li\u003e\r\n\u003cli\u003eProduct size: approx. 84 * 69 * 34 mm\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003ePackage List:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e1x Mini Thermostat Temperature Controller\u003c\/li\u003e\r\n\u003cli\u003e1x Waterproof Sensor\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003ePanel instruction\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cdiv\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eDisplay instruction: Three-digit LED + Minus digit + Status indicator light(Status indicator light(Cool, Heat)+Set indicator light(Set)) Key instruction:\"\" \"\"Key: the key to set;\"\" \"\"key: Up key;\"\" \"\"key: Down key;\"\" \"\":the key to turn on and off the power\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cdiv\u003e\n\u003cbr\u003e\u003cstrong\u003eKey operation instruction\u003c\/strong\u003e\n\u003c\/div\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eThe way to check parameter: Under normal working status, press\"\" \"\"key it displays temperature setting value; press \"\" \"\"key it displays the difference value.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cdiv\u003e\r\n\u003cdiv\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eThe way to set parameter: Under controller normal working status, press\"\" \"\"key for 3s or more to enter parameter modifying mode, and the \"\"Set\"\" indicator light on, screen displays the first menu code \"\"F1\"\". Press\"\" \"\"key or\"\" \"\" key to adjust up and down and display the menu item and the code of the menu item. Press\"\" \"\"key to display the parameter value of the current menu. Press both\"\" \"\" key and hold\"\" \"\"key or\"\" \"\" key simultaneously to choose and adjust the parameter value of the current menu value promptly. After finishing the setting, press and release the \"\" \"\"key instantly to save the parameter modified value and return to display the normal temperature value. If no key operation within 10 seconds, system won't save modified parameter, screen back to display normal temperature.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eRestore system data when electrified, system will check itself, screen will display \"\"Er\"\"if error exit, please press any key at this time, and it restores default value and enter into normal working mode. it is advised to reset the parameter value under such conditions \u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003c\/div\u003e\r\n\u003cdiv\u003e\n\u003cbr\u003e\u003cstrong\u003eOperation instruction\u003c\/strong\u003e\n\u003c\/div\u003e\r\n\u003cdiv\u003e \u003c\/div\u003e\r\n\u003cdiv\u003e\r\n\u003cdiv\u003eUnder controller normal working status, press and hold\"\" \"\"key for 3s can turn off the controller; Under controller \"\"off\"\" status, press and hold\"\" \"\" key for 1s can turn on the controller. Under the controller normal working status, screen displays the current measuring temperature value; also the controller can also switch the working mode between heating and cooling. Controller starts refrigerating with cool indicator light on when the measuring temperature value≥ temperature set value + difference value, and the refrigerating relay is connected; If the \"\"Cool\"\" indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature values≤ temperature set value, the Cool indicator light on, and \u003c\/div\u003e\r\n\u003cdiv\u003erefrigerating relay disconnects. System starts heating when the measuring temperature value≤ the temperature set value-difference value, and the \"\"Heat\"\" indicator light \u003c\/div\u003e\r\n\u003cdiv\u003eon, the heat relay connects; When the measuring temperature 2 temperature set value the \"\"Heat\"\" indicator light is off, and the heat relay disconnects.\u003c\/div\u003e\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cdiv\u003e\u003col\u003e\u003cli\u003e\u003ca href=\"http:\/\/archive.communica.co.za\/Content\/Catalog\/Documents\/D0124164360.pdf\"\u003eUser Manual - STC-3028\u003c\/a\u003e\u003c\/li\u003e\u003c\/ol\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Information\u003c\/h2\u003e\n\u003cdiv\u003e\u003ctable border=\"1\" cellpadding=\"7\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDual Display | Temperature and Humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Communica","offers":[{"title":"Default Title","offer_id":44755667091500,"sku":"BMT STC-3028 TEMP\/HUMID CONTROL","price":343.48,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0300\/5376\/1068\/files\/bmt-stc-3028-temphumid-control-998580.jpg?v=1757331135","url":"https:\/\/xytron.ae\/ar\/products\/bmt-stc-3028-temp-humid-control","provider":"Xytron","version":"1.0","type":"link"}